DESCRIPTION OF MINOR ERRORS OF THE EHR ELECTRO-HYDRAULIC SYSTEM

Flashing combination of
the diagnostic LED (7).
3x
1x
3x
2x
3x
4x
3x
6x
ELECTRO-HYDRAULIC SYSTEM
Error location
Right dynamometric pin (A)
Left dynamometric pin (A)
Lowering speed control (3)
Control setting switch (6)
F_02_174
Possible cause of the error
Faulty dynamometric pin
Faulty contact or interrupted conductor of the dynamometric
pin
Short-circuit of the dynamometric pin conductor
Possible overloading of the dynamometric pin
Faulty potentiometer of the control (3)
Faulty contact or interrupted conductor of the control
Faulty potentiometer of the switch (6)
Faulty contact or interrupted conductor of the switch