54. [Trap] In system group , it should not support external alarm.
55. [MIB-zyxelHwMonitor] The zyHwMonitorTemperatureIndex (OID:
1.3.6.1.4.1.890.1.15.3.26.1.2.1.1) value doesn't math the Web via SNMPc.
56. [PoE] When all PDs connect to device and reboot device, CLI will pop error message
during reboot process.
57. [PoE] When all PD Power exceeds threshold power, DUT should send PoE trap.
58. [Trap Group] The trap logs should be define the same in both CLI and SNMPc
59. [Trap Group] Both "eventOnTrap" or "eventClearTrap" should be clear defined in SNMPc
when Voltage event has been occurred or cleared
60. [MIB-zyxelCfm]The zyCfmManIpAddress (OID: 1.3.6.1.4.1.890.1.15.3.13.1.2.2) can't set
via SNMPc or MIB Browser.
61. [Trap Group] Both "eventOnTrap" or "eventClearTrap" should be clear defined in SNMPc
when temperature event has been occurred or cleared
62. [Trap Group] Both "eventOnTrap" or "eventClearTrap" should be clear defined in SNMPc
when fan speed event has been occurred or cleared
63. [MIB-zyxelIgmpSnooping] The zyIgmpSnoopingInfoVlanQueryPorts (OID:
1.3.6.1.4.1.890.1.15.3.31.2.2.1.3) should be 0x00:00:00:00:00:00:00:00, not
0x00:00:00:00.
64. [MIB-zyxelIgmpSnooping]The zyIgmpSnoopingGroupPorts (OID:
1.3.6.1.4.1.890.1.15.3.31.2.7.1.1.4) should be 0xf0:00:00:00:00:00:00:00, not
0xf0:00:00:00.
65. [MIB-zyxelIpForward] Using "Get" way to get zyxelIpRouteStatus (OID:
1.3.6.1.4.1.890.1.15.3.32.3) table value will fail. But using "Next Get" way is OK.
66. [MIB-zyxelIpv6] The zyIpv6DefaultGateway (OID: 1.3.6.1.4.1.890.1.15.3.34.1.5.1.7) can't
be set via SNMPc or MIB Browser.
67. [MAC-Pinning] The mac-pinning and port-security didn't enable at the same time.
68. [MIB-zyxelIpv6] When creating the max IPv6 rules and enable zyIpv6State (OID:
1.3.6.1.4.1.890.1.15.3.34.1.5.1.2), it only can active 94 IPv6 rules.
69. [Static Arp] when both Static Arp and VLAN 1's IP were duplicated, VLAN 1 should be able
to reset its IP back to default
70. [MIB-zyxelIpv6Ndp] The zyNdpPrefixValidLifetime (OID: 1.3.6.1.4.1.890.1.15.3.35.1.3.1.5)
can't set to max value via SNMPc or MIB Browser.
71. [MIB-zyxelIpv6StaticRoute] The zyIpv6StaticRouteNextHopIpAddress (OID:
1.3.6.1.4.1.890.1.15.3.37.1.2.1.5) can't be set via SNMPc or MIB Browser.
72. [Port Security] Enable port security address limit :16384, DUT only learn to 16211 MAC
Address.
73. [MIB-zyxelManagement] When using SilverCreek to test the zyxelManagement (OID:
1.3.6.1.4.1.890.1.15.3.49), CLI will pop error message - "arp_flush_by_iface : VPS not
found".
74. [System log] system log should not include the word "eventClearTrap" when the log has
been cleared
75. [MIB-zyxelMldSnoopingProxy] When setting the invalid value to
zyMldSnoopingProxyFilteringProfileRowStatus (OID: 1.3.6.1.4.1.890.1.15.3.51.1.2.1.6), it
should pop error message.
76. [Syslog] syslog should not include the word "eventClearTrap" when the log has been
cleared
77. [MIB-zyxelMldSnoopingProxy] Creating the zyMldSnoopingProxyVlanRowStatus (OID:
1.3.6.1.4.1.890.1.15.3.51.3.5.1.2) to 5 (createAndWait) or 4 (createAndGo) will fail via
SNMPc or MIB Browser.
78. [MIB-zyxelMldSnoopingProxy] The limiting value of the
zyMldSnoopingProxyUpstreamVlanLastMemberQueryInterval (OID:
1.3.6.1.4.1.890.1.15.3.51.3.6.1.5) doesn't match the CLI (1~8387584).
79. [MIB-zyxelMldSnoopingProxy] When using SilverCreek to test the
zyMldSnoopingProxyDownstreamVlanQueryInterval (OID:
1.3.6.1.4.1.890.1.15.3.51.3.7.1.2), it will pop error message - "Agent returned wrong
syntax for
ZYXEL-MLD-SNOOPING-PROXY-MIB:zyMldSnoopingProxyDownstreamVlanQueryInter
val.4094. Expected syntax of
ZYXEL-MLD-SNOOPING-PROXY-MIB:zyMldSnoopingProxyDownstreamVlanQueryInter
val.4094 to be INTEGER, not Gauge".