APV
APV_UF3 ATEX_UK-0_122018.indd
Relief Valve
DELTA UF3-ATEX
Instruction Manual UK-0
8.
Installation
8.1.
General terms
Installation has to be done in such a way that liquids can drain off
the valve housing. Vertical position is preferred.
Valves can be welded direct into the pipeline (valve insert
completely dismantable).
-
After the installation, the set value must be adjusted by a pressure
gauge.
Adjustment:
turn right
turn left
If required, the value can be corrected during production
by turning the adjusting screw at the spring cylinder.
Attention!
Observe Welding Instructions 8.2.
Conductive connection to the pipeline must be provided.
The integration into the operational potential equalization must be
guaranteed!
=
pressure increase
=
pressure reduction
UK
10