12. Service Instructions
12.5. Installation of valve
1. Place the complete valve insert carefully into the valve housing
(1).
2. Enter the screws (10) and tighten them crosswise.
3. UF3 valve with seat lift actuator: mount the pneumatic air lines.
4. Installation of valve feedback.
basic adjustment:
fine adjustment:
Fix the switch by the clamp screw.
Push the proximity switch into the holder
with a 2 mm distance to the operating cam
(12)
By slightly displacing the switch, the shift
point can be adjusted more precisely
if necessary. Observe the luminous
diode at the switch during this adjustment.