External I/O Control - Roland R1000 Series Manual

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Communication with the PLC
6.5

External I/O control

The system is normally controlled via the process channel. The exception is the signal
"Measurement start", which, for fast procedures, can also be controlled via the Optocoupler inputs
(IN). A mixed operation is also possible. The control cannot, however, be made simultaneously by
both signal sources.
The "Measurement start" signals can be initiated via the process channel or the opto couplers.
Simultaneous initiation is not possible. That means that the initiation of measurement start is not
accepted by optocouplers, if measurement start of the process channel is active or not processed.
The same applies to the other way.
Signal
Meaning
IN0
Measurement start input 1
IN1
Measurement start input 2
IN2
Measurement start input 3
Table: Optocoupler - inputs
The "Measurement start" inputs are linked in different combinations via AND. The following
configuration can be selected in the control unit:
IN0
IN0 and IN1
IN0 and IN1 and IN2
In addition the signals 0-, 1-, 2-sheet, ENABLE and warning are available for further processing via
Optocoupler (OUT).
Signal
Meaning
OUT0
Output 0-sheet
OUT1
Output 1-sheet
OUT2
Output 2-sheet
OUT3
Output ENABLE
OUT4
Warning
Table: Optocoupler – outputs
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
88
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
Notes
Optocoupler input 1
Optocoupler input 2,
Optocoupler input 3
Notes
1st Optocoupler output
2nd Optocoupler output
3rd Optocoupler output
4th Optocoupler output
5th Optocoupler output
If the external outputs or inputs are used, then the supply voltage for
Attention
the outputs / inputs needs to be connected.
Manual
Optocoupler inputs
24 V active
24 V active
24 V active
Optocoupler outputs
standard 0 V active (selection in the control unit
configuration)
standard 0 V active (selection in the control unit
configuration)
standard 0 V active (selection in the control unit
configuration)
standard 24 V active (cannot be selected for safety
reasons)
standard 0 V active (selection in the control unit
configuration)
B0060191 / Rev. 1.7

Advertisement

Table of Contents
loading

This manual is also suitable for:

L20

Table of Contents