Faults concerning Teach-In / Zero adjust

No.
Cause
150
Teach-In is not possible because
- the sheet is outside the measuring range of the sensors
(sheet too thin)
- no sheet is present.
- wrong sheet thickness or material was adjusted.
151
Teach-In is not possible because
- the sheet is outside the measuring range of the sensors
(sheet too thick).
- wrong sheet thickness or material was adjusted.
152
Zero adjust is not possible.
9.8

Faults concerning Sensors / Sensor cables

No.
Cause
155
Allocation of pair of sensors 1 is faulty
156
Allocation of pair of sensors 2 is faulty
157
Allocation of pair of sensors 3 is faulty
158
Allocation of pair of sensors 4 is faulty
160
Cable rupture at connection S1
161
Cable rupture at connection E1
162
Cable rupture at connection S2
163
Cable rupture at connection E2
164
Cable rupture at connection S3
165
Cable rupture at connection E3
166
Cable rupture at connection S4
167
Cable rupture at connection E4
If the fault messages of this group appear due to a mis-set system configuration (wrong number of sensors), then
simultaneously press all 4 operating keys and thus call up the configuration menu directly, and set the correct values
there. Only then the fault conditions are redressed.
9.9

Faults concerning Hardware

No.
Cause
170
AD converter defective.
171
Hardware does not fit to Software / Firmware.
172
Display defective
173
Internal fault SPI-BUS
175
Internal voltage is missing.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Manual
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
Fault messages, causes and remedies
Remedy
Measuring range see section 3.3 "sensor
diagrams" and 2.2 "system type"
Measuring range see section 3.3 "sensor
diagrams" and 2.2 "system type"
• In the „System adjust" parameters select
parameter „Sensor distance" and check the
distance.
• The distances of the sensors may not deviate for
more than ±10% among each others.
Remedy
Check wiring / allocation (sensor plugged in
correct socket ?) of sensor pair
Check wiring / allocation (sensor plugged in
correct socket ?) of sensor pair
Check wiring / allocation (sensor plugged in
correct socket ?) of sensor pair
Check wiring / allocation (sensor plugged in
correct socket ?) of sensor pair
Check cable and sensor which is connected at S1.
Check cable and sensor which is connected at E1.
Check cable and sensor which is connected at S2.
Check cable and sensor which is connected at E2.
Check cable and sensor which is connected at S3.
Check cable and sensor which is connected at E3.
Check cable and sensor which is connected at S4.
Check cable and sensor which is connected at E4.
Remedy
Call Roland service / exchange the system.
Install correct Firmware.
Call Roland service / exchange the system.
Call Roland service / exchange the system.
Call Roland service / exchange the system.