3.1 TABLE OF SPECIFICATIONS

Model Series
LS-200S - 125HP/90KW
LS-200S - 150HP/110KW
(I) An additional height of 25in/ 63.5cm is needed to service the separator element.
(II) Weight listed is for an open package. Add 590 lbs./268 kg. to weight and 1.5 in./38 mm to height for enclo-
sure package.
Noise levels vary with machine and enclosure. For machine dBA output,
COMPRESSOR:
Type:
Configuration:
Bearing Type:
Lubricant:
Coolant:
Sump Fluid Capacity:
System Fluid Capacity:
Duty Press:
Control Type:
Options:
MOTOR (60Hz):
Size:
Service:
Type:
Options:
MOTOR (50Hz):
Size:
Service:
Type:
Options:
3.2 LUBRICATION GUIDE- STANDARD COMPRES-
SORS
Before changing or recharging system fluid
always relieve all pressure from the sump tank
and all compressor lines.
Sullair standard compressors are filled with
Sullube fluid as factory fill.
Mixing of other lubricants within the compressor
unit will void all warranties.
Refer to Figure 3-1. Sullube fluid should be
changed every 8000 hours or once a year, whichev-
er comes first. The fluid should be changed more
Length
Width
in
mm
in
100
2540
60
100
2540
60
consult factory with machine serial number.
Positive displacement, fluid-lubricated, twin rotary screws
Single-stage geared integral drive
Anti-friction
Pressurized Sullube
See Sections 3.2,
3.3
9 gallons (34 liters)
14 gallons (53 liters)
100-110 psig (6.9-7.6 bar)
Electro-pneumatic
Higher duty pressures up to 175 psig (12.1 bar),
spiral valve, 24KT lubricant
125-150HP/90-110KW, 4-pole speed
3 ph, 60 Hz, 460 VAC, 40ºC ambient
ODP enclosure, NEMA frames 405TSC through 445TSC
TEFC enclosure, various voltages
125-150HP/90-110KW, 1500 RPM
3 ph, 50 Hz, 400 VAC, 40ºC ambient
ODP enclosure, NEMA frames 405TSC through 445TSC
IP23, TEFC enclosure, various voltages
SPECIFICATIONS
Height (I)
mm
in
1524
66.5
1524
66.5
and
3.4
on Lubrication
frequently under severe operating conditions, such
as high ambient temperatures coupled with high
humidity, or when high particulate level, corrosive
gases or strong oxidizing gases are present in the
air.
"The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in exposed
plant piping." (I)
PVC piping should not be used with Sullube. It
may affect the bond at cemented joints. Certain
other plastic materials may also be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Section 3
Weight (II)
mm
lb
kg
1690
4660
2114
1690
4980
2259
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-200sVcc-200s