BROMINE,
continued
Pollution Prevention and Waste Management
REQUIRED REAGENTS (USING POWDER PILLOWS)
Description
DPD Total Chlorine Reagent Powder Pillows .........1 pillow ............... 100/pkg.......... 21056-69
REQUIRED REAGENTS (USING ACCUVAC AMPULS)
DPD Total Chlorine Reagent AccuVac Ampuls .....1 ampule ................ 25/pkg.......... 25030-25
REQUIRED APPARATUS (USING POWDER PILLOWS)
Sample Cells, 10-20-25-mL, w/ cap ......................................................... 6/pkg.......... 24019-06
REQUIRED APPARATUS (USING ACCUVAC AMPULS)
Beaker, 50 mL............................................................... 1........................... each.............. 500-41
OPTIONAL REAGENTS
Chlorine Standard Solution, PourRite ampule, 25-30 mg/L, 2 mL ........ 20/pkg.......... 26300-20
DPD Total Chlorine Reagent, SwifTest .............................................. 250 Tests.......... 28024-00
Potassium Iodide Solution, 30 g/L............................................. 100 mL
Sodium Arsenite, 5 g/L..............................................................100 mL* MDB............ 1047-32
Sodium Hydroxide Standard Solution, 1.000 N ........................100 mL* MDB............ 1045-32
Sulfuric Acid Standard Solution, 1 N ........................................100 mL* MDB............ 1270-32
Water, deionized............................................................................................4 L.............. 272-56
OPTIONAL APPARATUS
AccuVac Snapper Kit.................................................................................. each.......... 24052-00
PourRite Ampule Breaker........................................................................... each.......... 24846-00
Cylinder, graduated, 25 mL ........................................................................ each.............. 508-40
ion
pH Meter, sens
1, portable................................................................... each.......... 51700-00
pH Indicator Paper, 1 to 11 pH units ................................................ 5 rolls/pkg.............. 391-33
Pipet, TenSette, 0.1 to 1.0 mL..................................................................... each.......... 19700-01
Pipet Tips, for 19700-01 TenSette Pipet ................................................. 50/pkg.......... 21856-96
Pipet Tips, for 19700-01 TenSette Pipet ............................................. 1000/pkg.......... 21856-28
For Technical Assistance, Price and Ordering
In the U.S.A.—Call 800-227-4224
Outside the U.S.A.—Contact the Hach office or distributor serving you.
* Contact Hach for larger sizes
Samples treated with sodium arsenite for manganese or
chromium interference will be hazardous wastes as regulated by
Federal RCRA for arsenic (D004). See Section 3 for more
information on proper disposal of these materials.
Quantity Required
84
Per Test
*
Unit
Cat. No.
MDB.............. 343-32