Controller Module (Ac); Power; Inter-Module Communications; Network - HID ACW2-XN Technical Service Manual

Web-based access control solution
Hide thumbs Also See for ACW2-XN:
Table of Contents

Advertisement

Controller Module (AC)

Power

Conditions
Supply at 12V DC

Inter-Module Communications

Connector
10-way connectors:
female on the left, male on the right

Network

Connector
RJ45
RS-485 Device Port (for linking a master AC to a slave AC)
Interface
Baud Rate
RS-485
38 400

Wiegand Module (AW2)

Power (At 12V DC)

Conditions
Relays idle, No readers Connected
Both relays activated, maximum reader load

Relays

Contact Rating
[10A, 28VDC]
[5A, 220VAC]
[12A, 120VAC]
Inter-Module Communications
Connector
10-way connectors:
Female on the left, male on the right

Wiegand Reader Port

Connector
10-way Screw Terminal Plugs
© 2017 HID Global Corporation. All rights reserved.
Protocol
Ethernet, 10/100 Base T, half or full duplex
Data Format
8 data bits, no parity, 1 stop bit
Configuration
Double Pole Single Throw
Purpose
Power and data lines to other modules
Reader Connections
12V, 5V, 0V, D0, D1, LED(Red), LED(Green), Buzzer, Hold, Shield
Web-Based Access Control Solution
Current
140 mA
Purpose
Power and data lines to other modules
Current
37 mA
503 mA
Contacts
Operations
> 100 000 (with MOVs installed
NO, NC, COM
across 12V inductive loads)
Technical Service Guide
Power
1.7 W
Power
0.44 W
6 W