Available Internal Data
See Appendix A - I/O Signal Descriptions on page 13 for additional details regarding each input/output. Unless
stated otherwise:
•
Values are subject to the same maximum and minimum restrictions of the ADM.
•
Some of the temperature data may have slight rounding errors compared to temperatures displayed on the ADM.
•
On some controlling devices, the byte order may need to be reversed (byte order within instance, least significant
-> most significant.
Automation Inputs (Signals from the Therm-O-Flow to the PLC)
Instance
Input Byte
Number
Index(es)
1
0 -1
2
2 - 3
3
4 - 5
4
6 - 7
5
8 - 9
6
10 - 11
7
12 - 13
8
14 - 15
9
16 - 17
10
18 - 19
11
20 - 21
12
22 - 23
13
24 - 25
14
26 - 27
15
28 - 29
16
30 - 31
17
32 - 33
18
34 - 35
19
36 - 37
20
38 - 39
21
40 - 41
22
42 - 43
23
44 - 45
24
46 - 47
25
48 - 49
26
50 - 51
27
52 - 53
28
54 - 55
29
56 - 57
30
58 - 59
31
60 - 61
32*
62 - 63
33*
64 - 65
34*
66 - 67
35*
68 - 69
36*
70 - 71
37*
72 - 73
3A5186B
Pump Actual Temperature, Primary
Platen Actual Temperature, Primary
Zone #1 Actual Temperature, Primary
Zone #2 Actual Temperature, Primary
Zone #3 Actual Temperature, Primary
Zone #4 Actual Temperature, Primary
Zone #5 Actual Temperature, Primary
Zone #6 Actual Temperature, Primary
Zone #7 Actual Temperature, Primary
Zone #8 Actual Temperature, Primary
Zone #9 Actual Temperature, Primary
Zone #10 Actual Temperature, Primary
Zone #11 Actual Temperature, Primary
Zone #12 Actual Temperature, Primary
Pump Setpoint Temperature Indication, Primary/Secondary
Platen Setpoint Temperature Indication, Primary/Secondary
Zone #1 Setpoint Temperature Indication, Primary/Secondary
Zone #2 Setpoint Temperature Indication, Primary/Secondary
Zone #3 Setpoint Temperature Indication, Primary/Secondary
Zone #4 Setpoint Temperature Indication, Primary/Secondary
Zone #5 Setpoint Temperature Indication, Primary/Secondary
Zone #6 Setpoint Temperature Indication, Primary/Secondary
Zone #7 Setpoint Temperature Indication, Primary/Secondary
Zone #8 Setpoint Temperature Indication, Primary/Secondary
Zone #9 Setpoint Temperature Indication, Primary/Secondary
Zone #10 Setpoint Temperature Indication, Primary/Secondary
Zone #11 Setpoint Temperature Indication, Primary/Secondary
Zone #12 Setpoint Temperature Indication, Primary/Secondary
Pump, Platen, Zones 1 – 3 States, Primary
Zones 4 – 8 States, Primary
Zones 9 – 12 States, Primary
Pump Setback Setpoint Temperature Indication, Primary/Secondary
Platen Setback Setpoint Temperature Indication, Primary/Secondary
Zone #1 Setback Setpoint Temperature Indication, Primary/Secondary
Zone #2 Setback Setpoint Temperature Indication, Primary/Secondary
Zone #3 Setback Setpoint Temperature Indication, Primary/Secondary
Zone #4 Setback Setpoint Temperature Indication, Primary/Secondary
Description
Available Internal Data
Units
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
9