Maintenance
Maintenance
Software Update Procedure
When software is updated on the ADM, the software is
then automatically updated on the CGM and all other
connected Graco Control Architecture components.
1. At the ADM, turn the power switch to Off.
2. Remove the ADM from the bracket.
3. Use a hex key to remove the token access panel.
F
. 6: Token Location
IG
4. Insert and press the software upgrade token firmly
into the slot.
5. Turn the power switch to On.
A status is shown while software is updating to indi-
cate progress. To prevent corrupting the software
load, do not remove the token until the status screen
disappears.
8
NOTICE
6. The Graco Splash screen is displayed until commu-
nication with other modules is established.
7. Wait for the update to complete. An approximate
time to completion displays below the progress bar.
8. When the update is completed successfully, press
the
key.
9. Remove the token and replace the token access
panel.
NOTE: The software version history for each system
can be viewed in the technical support section at
www.graco.com.