Graco Therm-O-Flow 25C994 Instructions Manual page 21

Communications gateway module. installation kit
Table of Contents

Advertisement

Description
Get Pump B Setback Setpoint
165
Temperature
Get Platen B Setback Setpoint
166
Temperature
Get Zone 1, B Sec. Setback Set-
167
point Temperature
Get Zone 2, B Setback Setpoint
168
Temperature
Get Zone 3, B Setback Setpoint
169
Temperature
Get Zone 4, B Setback Setpoint
170
Temperature
Get Zone 5, B Setback Setpoint
171
Temperature
Get Zone 6, B Setback Setpoint
172
Temperature
Get Zone 7, B Setback Setpoint
173
Temperature
Get Zone 8, B Setback Setpoint
174
Temperature
Get Zone 9, B Setback Setpoint
175
Temperature
Get Zone 10, B Setback Set-
176
point Temperature
Get Zone 11, B Setback Set-
177
point Temperature
Get Zone 12, B Setback Set-
178
point Temperature
179 -
Reserved for Future Use
~65k
3A5186B
Provides the selected Secondary System Zone Setback Mode
setpoint temperature setting to the interface. Temperature Units
match units of the ADM. Values are in tenths of a degree (for
example, a value of 2505 corresponds to 250.5°F). These
pointer designations are typically used for PROFIBUS and
PROFINET applications.
Appendix B - Data Exchange Interface
Comments
Read/
Write
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read