Available Internal Data

See Appendix A – I/O Signal Descriptions for
additional details regarding each input/output.
Unless stated otherwise,
Bytes are stored in each instance in little endian
order. (byte order within instance: least
significant...most significant)
Values are subject to the same maximum and
minimum restrictions of the ADM.
Input Data (Signals from HFR/NVH to
PLC/ Controlling Logic)
In-
Byte
Input
stance
(s)
Bit(s)
0
0 – 1
I00 –
I15
1
2- 3
I16 –
I31
2
4 -5
I32 –
I47
3
6 – 7
I48 –
I63
4
8 - 9
I64 –
I79
5
10 -
I80 –
13
I111
6
14 -
I112 –
17
I143
7
18
I144 –
I151
8
19
I152 –
I159
9
20
I160 –
I167
10
21
I168
Description
Current Pressure, Blue
Pump
(in 0.01 of bar units)
Current Pressure, Red
Pump
(in 0.01 of bar units)
Current Flow Rate
(in 0.01 of cc/sec or g/sec
units)
Flow Rate or pressure Set
Point for Current or Next
Dispense
(in 0.01 cc/sec, 0.01 g/sec or
0.01 bar units)
Current Dispense Duration,
which counts up starting from
0 (in 0.01 second units).
Amount for current Dispense
(In 0.01 CC or 0.01 Gram
units, starting from 0)
Amount Set point for Current
Dispense (In 0.01 CC, 0.01
Gram, or 0.001 second units,
Shot & Sequence Modes)
Current Mode Selected.
Current Active Shot Number
(1-100, Shot Mode) or
Sequence Position (1-20,
Sequence Mode).
Current Sequence number (1-
26, for A-Z) selected
(Sequence mode only)
Heart Beat from HFR/NVH
MCM (#)
CGM Interface Manual, HFR/ NVH (Small Map with Data Exchange) Applications, March 25, 2022, Page 7 of 23
I169
I170
I171
I172
I173
I174
I175
11
22 -
I176 –
23
I191
12
24 -
I192 –
25
I207
13
26 –
I208 –
27
I223
14
28 -
I224 –
31
I255
Notes:
* - See Appendix B for Data Exchange Interface details.
# - Heart Beat signal change from high to low, and low to
high at a 0.25 hertz rate.
% - Refer to Table for Error Numbers (Appendix C), and
appendix B #151 & 152 for details.
$ - Refer to Appendix B or Data Exchange section (starting
on #161) on how to set up the configurable data
registers.
Dispense Valve Open/
Dispense Active
Recirculation Valve Opened
(HFR Only)
System Startup Command
Active
Pumps are Parked
High Pressure Recirculation
Active (NVH Only)
Cold Startup Active (Currently
NVH Only)
System is "Ready" for
Dispense Request.
Configurable Data Element 1
($). Default: Additional
Status Bits (See Appendix B,
#140)
Configurable Data Element 2
($). Default: Error Number
Requiring Acknowledgement
(0 = None) (%)
Data Exchange Interface -
Pointer Last Serviced (*)
Data Exchange Interface –
Input Data Element (*)