Appendix A - I/O Signal Descriptions

Temperature Setpoint Zone Designation Table

The following table shows the setpoint designations in
output instance 2 used to command the Therm-O-Flow
temperature zones to the corresponding setpoint. Prior
to writing to instance 2, the PLC needs to write the
desired temperature setpoint (in tenths of a degree for
the selected temperature unit of measure) to output
instance 3 for the selected zone. After the zone desig-
nation has been written, the PLC can monitor the set-
point change by monitoring the correct setpoint
indications: input instances 15-28 or 32-45.
0
No Zone Selected
1
Pump Setpoint Temperature, Primary
2
Platen Setpoint Temperature, Primary
3
Zone 1 Setpoint Temperature, Primary
4
Zone 2 Setpoint Temperature, Primary
5
Zone 3 Setpoint Temperature, Primary
6
Zone 4 Setpoint Temperature, Primary
7
Zone 5 Setpoint Temperature, Primary
8
Zone 6 Setpoint Temperature, Primary
9
Zone 7 Setpoint Temperature, Primary
10
Zone 8 Setpoint Temperature, Primary
11
Zone 9 Setpoint Temperature, Primary
12
Zone 10 Setpoint Temperature, Primary
13
Zone 11 Setpoint Temperature, Primary
14
Zone 12 Setpoint Temperature, Primary
15
Pump Setpoint Temperature, Secondary
16
Platen Setpoint Temperature, Secondary
17
Zone 1 Setpoint Temperature, Secondary
18
Zone 2 Setpoint Temperature, Secondary
19
Zone 3 Setpoint Temperature, Secondary
20
Zone 4 Setpoint Temperature, Secondary
21
Zone 5 Setpoint Temperature, Secondary
22
Zone 6 Setpoint Temperature, Secondary
23
Zone 7 Setpoint Temperature, Secondary
24
Zone 8 Setpoint Temperature, Secondary
25
Zone 9 Setpoint Temperature, Secondary
26
Zone 10 Setpoint Temperature, Secondary
27
Zone 11 Setpoint Temperature, Secondary
28
Zone 12 Setpoint Temperature, Secondary
61
Pump Setback Setpoint Temperature, Primary
62
Platen Setback Setpoint Temperature, Primary
Zone 1 Setback Setpoint Temperature, Pri-
63
mary
Zone 2 Setback Setpoint Temperature, Pri-
64
mary
16
Description
Zone 3 Setback Setpoint Temperature, Pri-
65
mary
Zone 4 Setback Setpoint Temperature, Pri-
66
mary
Zone 5 Setback Setpoint Temperature, Pri-
67
mary
Zone 6 Setback Setpoint Temperature, Pri-
68
mary
Zone 7 Setback Setpoint Temperature, Pri-
69
mary
Zone 8 Setback Setpoint Temperature, Pri-
70
mary
Zone 9 Setback Setpoint Temperature, Pri-
71
mary
Zone 10 Setback Setpoint Temperature, Pri-
72
mary
Zone 11 Setback Setpoint Temperature, Pri-
73
mary
Zone 12 Setback Setpoint Temperature, Pri-
74
mary
Pump Setback Setpoint Temperature, Sec-
75
ondary
Platen Setback Setpoint Temperature, Sec-
76
ondary
Zone 1 Setback Setpoint Temperature, Sec-
77
ondary
Zone 2 Setback Setpoint Temperature, Sec-
78
ondary
Zone 3 Setback Setpoint Temperature, Sec-
79
ondary
Zone 4 Setback Setpoint Temperature, Sec-
80
ondary
Zone 5 Setback Setpoint Temperature, Sec-
81
ondary
Zone 6 Setback Setpoint Temperature, Sec-
82
ondary
Zone 7 Setback Setpoint Temperature, Sec-
83
ondary
Zone 8 Setback Setpoint Temperature, Sec-
84
ondary
Zone 9 Setback Setpoint Temperature, Sec-
85
ondary
Zone 10 Setback Setpoint Temperature, Sec-
86
ondary
Zone 11 Setback Setpoint Temperature, Sec-
87
ondary
Zone 12 Setback Setpoint Temperature, Sec-
88
ondary
3A5186B