Advertisement

Quick Links

Instructions – Parts List
Parts
Gun Flush Boxt Module
100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure
Part No. 244105
U.S. PATENT NO. 6,554,204
Read warnings and instructions.
Keep for reference.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2000, Graco Inc. is registered to I.S. EN ISO 9001
309227D

Advertisement

Table of Contents
loading

Summary of Contents for Graco Gun Flush Box 244105

  • Page 1 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure Part No. 244105 U.S. PATENT NO. 6,554,204 Read warnings and instructions. Keep for reference. GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 2000, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2: Table Of Contents

    ....... . . Graco Standard Warranty ..... . .
  • Page 3: Warnings

    WARNING FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire, explosion, or electric shock, which can result in serious injury. D Ground the equipment and the object being sprayed. See Grounding on page 7. D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvent or the fluid being sprayed.
  • Page 4 D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
  • Page 5: Introduction

    Traditional flushing procedures expose the operator to your local Graco distributor. atomized solvent and accidental gun discharge. The D Always turn off the electrostatics before placing Gun Flush Box contains the solvent and prevents the gun in the Gun Flush Box and whenever you accidental gun triggering with safety interlocks.
  • Page 6: Installation

    8, as a guide for installing the Gun Flush Box. Contact ted in the spray booth. Install the gun flush box(es), your Graco distributor for an actual system design. using the mounting holes as a template. See Fig. 1 for dimensions.
  • Page 7: Enclosed Waste Container

    Installation Enclosed Waste Container Grounding WARNING WARNING FIRE, EXPLOSION, AND ELECTRIC TOXIC FLUID HAZARD SHOCK HAZARD To reduce the risk of splashing, a minimum of two To reduce the risk of fire, explosion, or feet (0.6 m) of straight plastic or grounded metal electric shock, the system must be pipe or tubing must be connected between the Gun properly grounded.
  • Page 8 Installation Typical Installation of Gun Flush Box in PrecisionMix System Fig. 4 309227...
  • Page 9: Connect Tubing To The Pneumatic Controls

    Installation Connect Tubing to the Pneumatic Controls Fig. 5 shows the bottom of the Gun Flush Box. The 1. Connect a 5/32” (4 mm) OD tube between the air four bulkhead fittings are labeled: supply and the P bulkhead. Use a clean, dry air supply;...
  • Page 10: Trigger Height Adjustment

    Trigger Height Adjustment Follow this procedure to ensure the gun triggers prop- 5. Raise the cylinder (M) until the pin (N) opens the erly during a purge. trigger fully. See Fig. 8. 1. Insert the gun into the Gun Flush Box. 6.
  • Page 11: Operation

    Operation PrecisionMixt II Controller Operation See your PrecisionMix II system manual 308916 for operation instructions. Operating Checklist Check the following list daily, before starting to operate ____ 7. All electrically conductive objects in the spray the system, to help ensure safe, efficient operation. area, including paint containers;...
  • Page 12: Troubleshooting

    Troubleshooting Problem Cause Solution Gun is in the Gun Flush Box, but Air is shut off. Turn on the air to the system. the system will not purge or mix. Gun switch is not activating. Test the switch. Replace it if it is dam- aged.
  • Page 13: Maintenance

    Maintenance Daily Weekly Every two weeks, minimum Gun Flush Box Keep the inside as clean as Clean the inside and out- Enclosure possible. Clean with a com- side of the enclosure with a patible solvent. compatible solvent. Door Keep hinge holes as clean Grease hinges.
  • Page 14: Parts

    Parts Detail A 6, 7, 8 8, 41 21, 22 6, 7, 8 6, 7, 8 See Detail A 42, 43, 44 9, 10 9, 10 Output to Interlock Trigger Input Gun In Box Output Air Inlet NOTE: Grease all cylinders and sensors with grease.
  • Page 15 Parts Ref. Part No. Description Qty. Ref. Part No. Description Qty. 196709 PANEL, cabinet, left 196708 ARM, lever 196710 PANEL, cabinet, right 551793 CYLINDER, air, 0.438 dia. 196711 COVER, cabinet 551890 NUT, jam, hex, 3/8–24 196712 WRAPPER, cabinet 626523 BUTTON, cylinder 626489 COVER, cylinder 551786...
  • Page 16: Accessories

    Graco Delta Sprayt Gun 570123 Wall Mount Kit 196770 Graco Alpha Gun For mounting the Gun Flush Box to the spray booth 196771 Graco Alpha Plus, Alpha Plus with wall. RAC Tip 196767 Devilbiss JGA/MSA* Gun Flush Box Retrofit Kits for PrecisionMix II Part No.
  • Page 17: Technical Data

    Technical Data Weight ............22 lbs.
  • Page 18: Graco Standard Warranty

    Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

Table of Contents