Table 2-8 Relationship Between Each Circuit On The Dli And Lens - NEC NEAX 2400 ICS Manual

Digital remote unit system
Hide thumbs Also See for NEAX 2400 ICS:
Table of Contents

Advertisement

4. DATA PROGRAMMING PLAN FOR DRU
This section explains the relationship between each circuit on the DLI card and LENS (Line Equipment Num-
bers).
4.1 Relationship between Each Circuit on the DLI Card and LENS
Table 2-8 shows the relationship between each circuit on the DLI card and LENS.

Table 2-8 Relationship between Each Circuit on the DLI and LENS

GROUP LEVEL
(30 LC/30 ELC MODE)
7
ODD
6
No.
GROUP
5
01, 03,
4
05, 07,
VOICE
3
09, 11,
13, 15,
2
17, 19,
21,
23,
1
0
7
EVEN
No.
6
GROUP
5
00, 02,
4
04, 06,
VOICE
3
08, 10,
12, 14,
2
16, 18,
20,
22,
1
0
Note :
PA-2DAID card is equal to two PA-DAIA cards in all respects.
PA-DAIA
(15 DLC MODE)
15
Not used
14
DATA
13
29
12
28
11
27
VOICE
10
26
VOICE
9
25
8
24
7
23
6
22
DATA
5
21
4
20
VOICE
3
19
2
18
VOICE
1
17
0
16
ND-45383 (E)
(23 ELC MODE)
7
Not used
6
14
5
DATA
13
4
12
VOICE
7
Not used
6
14
5
VOICE
13
4
12
3
11
2
10
DATA
1
9
0
8
VOICE
3
11
2
10
VOICE
1
9
0
8
PA-DAIC
(11 DLC + 1 ELC
15
14
DATA
13
12
Not used
11
10
VOICE
9
8
7
Not used
6
22
DATA
5
21
4
20
3
VOICE
19
2
18
VOICE
1
17
0
16
Revision CD 1.0
MODE)
7
6
5
4
Not used
7
6
5
4
3 Not used
2
10
1
DATA
9
0
8
3
11
2
10
VOICE
1
9
0
8
CHAPTER 2
Page 23

Advertisement

Table of Contents
loading