SYMBOL
DLI
When setting channel number of the signal data link to "18".
When setting channel number of the signal data link to "19".
When setting channel number of the signal data link to "23".
(Standard Setting)
*This switch setting must agree with the switch setting on the associated DRE card in DRU-23-S3.
Note 2: Switch setting when specifying band rate of data transmission *
64 Kbps
48/56 Kbps
*This switch setting must agree with the switch setting on the associated DRE card in DRU-23-S3.
Note 3: Switch setting for 12 Multi Frame/24 Multi Frame Format
12 Multi Frame Format (D4)
24 Multi Frame Format (ESF)
CHAPTER 3
Page 88
Revision CD 1.0
CIRCUIT CARD
PA-DAIC
ND-45383 (E)
Contents
Static Sensitive
Handling
Precautions Required
SW2
1 2 3 4 5 6 7 8
ON
SW2
1 2 3 4 5 6 7 8
ON
SW2
1 2 3 4 5 6 7 8
ON
SW2-1
:
ON
:
OFF
SW2-2
ON
OFF
ATTENTION