Check Of Battery Operation When Power Supply Failure To The Dru - NEC NEAX 2400 ICS Manual

Digital remote unit system
Hide thumbs Also See for NEAX 2400 ICS:
Table of Contents

Advertisement

A
Check lamp indications on the DRE
card in the DRU
END

2.4 Check of Battery Operation when Power Supply Failure to the DRU

START
Unplug the AC cord of the DRU
from the AC outlet
Plug the AC cord of the DRU into
the AC outlet
END
Confirm that the lamp indications of the DRE card as shown be-
low.
LAMP NAME
LINK (G)
ALM (R)
LB (R)
When the lamp indications are as shown above, perform the fol-
lowing loop-back tests.
• Loop-back test between the DLI and the transmission equip-
ment.
(Refer to Paragraph 3.3 in Chapter 5)
Confirm that the system message "13-Q" is displayed.
Confirm that the POWER lamp of the DRU illuminates.
Confirm that the system message "13-R" is displayed.
ND-45383 (E)
Contents
Static Sensitive
Handling
Precautions Required
LAMP
INDICATION
ON
OFF
OFF
Revision CD 1.0
ATTENTION
CHAPTER 4
Page 113