NEC NEAX 2400 ICS Manual page 100

Digital remote unit system
Hide thumbs Also See for NEAX 2400 ICS:
Table of Contents

Advertisement

SYMBOL
DLI
Note 8: Switch setting for the PAD value for a case where the line of DLI card is connected via the Network.
0 dB (For in-premise direct installation)
2 dB
5 dB
8 dB
Note 9: Switch setting for bit rate of D
64 K (Standard Setting)
64 K INV
56 K
48 K
Note 10: Switch setting for designating the case where simultaneous communications of voice and APA/APR (Analog
Port Adapter) are performed or the case where the Data Adapter is used. *
SW3-3: for No. 0 ~ 3 circuit
SW3-4: for No. 4 ~ 7 circuit
SW3-5: for No. 8 ~ 10 circuit
When simultaneous communications of voice and APA/APR
(Analog Port Adapter) are performed.
(In this case, the Data Adapter cannot be used.)
When the Data Adapter is used.
*This switch setting is effective when using DRU-23-S3 by 11DLC + 1ELC mode. When DRU-23-S3 is used
by 23ELC mode, set these switches to OFF.
CHAPTER 3
Page 90
Revision CD 1.0
CIRCUIT CARD
PA-DAIC
term
Data Port
ND-45383 (E)
SW0-1
SW0-2
:
OFF
OFF
:
ON
OFF
:
OFF
ON
:
ON
ON
SW0-3
SW0-4
:
OFF
OFF
:
ON
OFF
:
OFF
ON
:
ON
ON
SW3-3/3-4/3-5
ON
OFF
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required

Advertisement

Table of Contents
loading

Table of Contents