"13-O": Digital Line Failure
(1) Meaning
The system message "13-O" indicates that such a fault as a frame loss, multi-frame loss, etc. has occurred more
than 16 times in a one-hour period consecutively during data transfer from the NEAX2400 IMS to the DRU.
(2) Related System Messages
If the fault of the digital line is restored to normal, the system message "13-P" is printed out.
(3) Example of Printout
SYSTEM MESSAGE 13-O [MN]
NEC TOKYO
LP00-0-ACT
1: 0701 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
(4) Message Detail Data
1: XX 0X
Kind of fault
01: Frame loss PCM down
02: Bit error more than 10
03: Slip detected
04: Remote office alarm detected
06: Multiframe loss
07: Frame loss PCM down (Continuous)
08: Multiframe loss (Continuous)
Accommodated location of detected DLI card
(Refer to paragraph 2.1.1)
MG
(5) Diagnostic from System Message
Refer to System Message "13-N".
DIGITAL LINE FAILURE
MAY 14 10:30
-4
U
G
MG: Module Group
U:
Unit
G:
Group