A press on the push switch (SW1) [3] while LED6 [2]
is flashing will cancel the transmission.
LED1 LED2 LED3
2
6
BAT1
1
1
SW3
SW2
LED5
SW4
[1]
LED6
LED4
IC6
[2]
SW1
[3]
CN3
CN2
F-1-151
18) Check to see that the communication between the
controller and its host machine is normal.
Connect the host machine's power plug, and turn on
the power switch; then, check to see that LED2
(orange) [2] flashes.
[2]
LED1 LED2 LED3
2
6
BAT1
1
1
SW3
SW2
LED5
SW4
LED6
LED4
IC6
SW1
CN3
CN2
F-1-152
19) Press the Start key on the host machine; then,
check that LED3 (pink) flashes each time delivery
is made.
[1]
LED1 LED2 LED3
2
6
BAT1
1
1
SW3
SW2
LED5
SW4
LED6
LED4
IC6
SW1
CN3
CN2
F-1-153
1
2
CN4
1
2
CN4
1
2
CN4
20) Attach the switch settings label [1] to the top cover
of the controller, and record the new switch
settings.
21) Fix the top cover [2] of the controller in place
using 2 screws [3]. When doing so, check to be sure
that the cable of the power supply unit is fixed in
place to the cable guide inside the controller and is
not trapped by the top cover [2].
[2]
[3]
F-1-154
Chapter 1
[3]
[1]