Configuring for UDP
Point-to-Point
72
Figure 3-35. UDP Point-to-Point Menu
Use UDP point-to-point configuration to send information to a single
device.
—Enable/Disable the serial data port.
Status
—UDP Point-to-Point. This is the type of IP port
IP Protocol
offered by the transceiver's serial device server.
[
TCP, UDP; TCP
Remote IP Address
sent to this IP address. To reach multiple Remotes in the net-
work, use UDP Point-to-Multipoint.
[
Any legal IP address; 0.0.0.0
Remote IP Port
received through the serial port on the transceiver.
[
1–64,000; 30010
Local IP Port
through to the serial port. The application connecting to this
transceiver must use this port number.
[
1–64,000; 30010,
Packet Redundancy Mode
Serial Packet Redundancy mode must match (Single Packet
mode vs. Packet Repeat mode). This is because a transceiver,
when in Packet Repeat mode, sends 12 extra characters
(sequence numbers, etc.) to control the delivery of the
repeated data. Misconfigurations might result in undesired
operation.
Data Baud Rate
bits-per-second. [
Byte Format
stop bits. [
7N1, 7E1, 7O1, 8N1, 8E1, 8O1, 8N1, 7N2, 7E2, 7O2, 8N2,
8E2, 8O2; 8N1
Mercury Reference Manual
Invisible place holder
]
—Data received through the serial port is
]
—The destination IP port for data packets
]
—Port number where data is received and passed
]
—For proper operation, all radios'
—Data rate (payload) for the
1,200–115,200; 19200
—Formatting of data bytes. Data bits, parity and
]
port, in
COM
]
05-4446A01, Rev. C