Interactive Diags

Select MONITORING from the Main Menu. Select DIAGNOSTICS
from the Monitoring menu. Select INTERACTIVE DIAGS from the
Diagnostics menu.
The Interactive Diags screen appears, as shown in
Figure
5-27.
You use this screen for selecting the type of hardware diagnostics
you wish to view. You can set up four fields, each with three
options; yes , no , or periodically .
Yes ( y ) always records data with errors. No ( n ) never records data
with errors. Periodically ( p ) records data with errors every 5
seconds. Periodical error logging may degrade bridge
performance.
Figure 5-27 Interactive Diags
Code Checksum: Text Field. This records the code checksum.
The code checksum test performs a 32-bit cyclical redundancy
check (CRC) which verifies that the code is not corrupted.
CPU ID PROM Checksum: Text Field. This verifies the ID PROM
of the CPU.