3Com LinkBuilder MSH User Manual page 210

4 port ethernet bridge module
Table of Contents

Advertisement

A-2
C
A: L
HAPTER
We recommend that the link method is only used when VT100
management is not possible, for example, when you've forgotten
your password, as this method involves physically removing and
installing the module twice. For information on resetting the
module via VT100, see
To reset the bridge module:
1 Remove the module from the LinkBuilder MSH chassis.
2 Change the link to the reset position, see
Figure A-2 The Link In The Reset Position
3 Install the module into the LinkBuilder MSH chassis.
4 When the module has finished its self-test (self-test is indicated by
the PWR LED flashing), remove it from the LinkBuilder MSH
chassis.
5 Change the link to the normal position, see
Figure A-3 The Link In The Normal Position
6 Install the module into the LinkBuilder MSH chassis. The module is
now reset to its default settings.
S
INK
ETTINGS
Erasing All Changes on page
2-27.
Figure
A-2.
Figure
A-3.
DUA1860-0AAA01