Zone Programming - Paradox Digiplex EVO48 V1.20 Installation Manual

High security and access system
Table of Contents

Advertisement

Enter Section [0400], then
enter the number of the
zone you want to program
Enter the zone's 8-digit
serial and 3-digit input
number (The input number
is not needed for module
with only one input)
Enter the zone's parameters
(01) (*2*****) default
Enter the zone's report
codes
(00) (00) (00) (00) default
Enter the zone's label
Press [ENTER] to save and
go to the next zone
Pressing [CLEAR] twice will
exit the zone programming
menus. Press [ENTER]
before pressing clear to
save your modifications.

Zone Programming

4
In any Zone Programming option, pressing [ACC] will save the data and go
to the next zone on the same option screen. Pressing [TRBL] will save the
data and go to the previous zone on the same option screen.
Zone Definition
Partition
_____
_____
0 - Disabled (default)
1 - Assigned to Partition 1
1 - Entry Delay 1
(default)
2 - Entry Delay 2
2 - Assigned to Partition 2
3 - Follow
3 - Assigned to Partition 3
4 - Instant
4 - Assigned to Partition 4
5 - 24Hr Buzzer
5 - Assigned to Partition 5
6 - 24Hr Burglary
6 - Assigned to Partition 6
7 - 24Hr Hold-up
7 - Assigned to Partition 7
8 - 24Hr Gas
8 - Assigned to Partition 8
9 - 24Hr Heat
A - 24Hr Water
B - 24Hr Freeze
C - Delayed 24Hr
Fire
D - Standard 24Hr
Fire
E - Stay Delay 1
F - Stay Delay 2
.
Alarm Restore
Alarm Report Code
Report Code
__ / __
__ / __
Ademco slow, Silent Knight fast, SESCOA, Ademco express or Pager formats:
Key-in desired 2-digit hex values from 00 to FF.
Ademco format:
Use section [4032] to program a set of default Ademco report codes from the Auto
Report Code Programming on page 26. Then to program the remaining report
codes or to change some of the defaults, enter the individual sections and key-in
the desired 2-digit hex value found in the Appendix 2: Contact ID Report Code List
on page 42.
SIA format:
Use section [4032] to program a set of SIA report codes from the Auto Report Code
Programming on page 26. Codes that have not been set to default can be set to
default manually by entering FF in the appropriate section. To disable the reporting
of an event, enter 00 in the appropriate section
Keypad
Hardwired
Keypad Zone
SN#: 1A000252
Device A
Control Panel
C
OMMUNICATION
SN#:020000A2
Input Terminals
1
2
3
4
5
6
7
8
APR3-ZX8 Module
SN#: 34000041
Hardwired
Input Terminals
Device B
1
2
3
4
5
6
Zone#
Section#
Detector A:
1 =
[0001]
Hardwired Device A:
2 =
[0002]
Hardwired Device B:
3 =
[0003]
Hardwired Device C:
4 =
[0004]
Zone Option
1 2 3 4 5 6 7 8
[1] Auto Zone Shutdown Enabled
[2] Bypass Enabled (default)
[3] Stay Zone
[4] Force Zone
[5]
off
off
on
on
[7] Intellizone
[8] Delay before Transmission
Tamper Report
Code
__ / __
Detector A
SN#: 21000033
Combus
N
ETWORK
Hardwired
Input 5
Device C
7
8
Serial#
Input#
21000033
N/A
1A000252
N/A
020000A2
002
34000041
005
[6]
Zone Alarm Type
off
Steady Alarm
on
Pulsed Alarm
off
Silent Alarm
on
Report Only
Tamper Restore
Report Code
__ / __
EVO Control Panel 9