Danfoss VLT Brake Resistor MCE 101 Design Manual page 36

Vlt frequency converters fc 51,fc 102,fc 202,fc 301,fc 302, fc 360,fcd 302, vlt 800
Table of Contents

Advertisement

Selection Guide
40% duty cycle, vertical braking, S2, T2, T4
Frequency converter data
P
Mains
m
type
[kW]
S2
1.5
S2
2.2
T2
1.5
T2
2.2
T2
3.7
T4
1.5
T4
2.2
T4
3
T4
4
T4
5.5
T4
7.5
T4
11
8
8
T4
15
T4
18.5
T4
22
Table 8.2 S2, T2, T4, Vertical Braking 40% Duty Cycle
34
Design Guide
FC 51
R
R
R
min
br,nom
rec
[Ω]
[Ω]
[Ω]
60.0
70.9
70
40.0
47.6
48
60.0
70.9
70
40.0
47.6
48
23.0
27.7
27
234
274.8
270
157
184.4
200
113
133.7
145
83.0
98.9
110
60.0
71.2
80
44.0
51.8
56
29.0
34.8
38
21.0
25.3
28
17.0
20.4
22
14.0
17.1
19
Danfoss A/S © Rev. 05/2014 All rights reserved.
Vertical braking 40% duty cycle
Brake resistor data
Danfoss part number
Screw
P
Wire IP54
terminal
br,cont.
[kW]
IP21
0.570
175u3302
175u3404
0.960
175u3303
175u3406
0.570
175u3302
175u3404
0.960
175u3303
175u3406
1.400
175u3305
175u3410
0.570
175u3311
175u3418
0.960
175u3312
175u3420
1.130
175u3313
175u3422
1.700
175u3314
175u3424
2.200
175u3315
175u3138
3.200
175u3316
175u3428
5.000
-
-
6.000
-
-
8.000
-
-
10.000
-
-
Installation
Cable
cross-
Screw
Bolt
section
terminal
connection
2
IP65
IP20
[mm
]
175u3403
-
1.5
175u3405
-
1.5
175u3403
-
1.5
175u3405
-
1.5
175u3409
-
1.5
175u3417
-
1.5
175u3419
-
1.5
175u3421
-
1.5
175u3423
-
1.5
175u3139
-
1.5
175u3427
-
1.5
-
175u3236
1.5
-
175u3237
2.5
-
175u3238
4
-
175u3203
4
Thermo
relay
[A]
2.7
4.2
2.7
4.2
6.8
1.4
2.1
2.7
3.7
5
7.1
11.5
14.7
19
23
MG90O202

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents