Setup In The Plc; Copy Device Description File - LinMot C1150-SE-XC-0S Interface Manual

Ethercat soe profile interface
Hide thumbs Also See for C1150-SE-XC-0S:
Table of Contents

Advertisement

2

Setup in the PLC

In the following steps the integration of a LinMot EtherCAT Sercos Servo Drive in the
PLC is described. In the example a Beckhoff master PLC is used. The easiest way is
the online configuration when the device is connected to the EtherCAT network.
2.1

Copy Device Description File

The LinMot Servo Drive is described with *.xml device description file distributed with
the LinMot-Talk software. This file is only used when offline configuration is desired.
Copy this file to PLC so it can access it.
Example Source path of EtherCAT Device description file:
C:\Programme\LinMot\LinMot-Talk 6.5 Build
20160205\Firmware\Interfaces\EtherCAT\XML\ NTIL_SoE_Servos_V1_3.xml
Example Destination path of EtherCAT Device description file:
TwinCAT 2:
C:\TwinCAT\Io\EtherCAT\ NTIL_SoE_Servos_V1_3.xml
TwinCAT 3:
C:\TwinCAT\3.1\Config\Io\EtherCAT\ NTIL_SoE_Servos_V1_3.xml
Omron:
C:\OMRON\Sysmac Studio\IODeviceProfiles\EsiFiles\UserEsiFiles
NTIL_SoE_Servos_V1_3.xml
If this is done the PLC should recognize the corresponding LinMot drives on the
EtherCAT fieldbus automatically.