Output Types - Danfoss PLUS+1 MC0XX-1 series Technical Information

Table of Contents

Advertisement

Technical Information
PLUS+1® MC0XX-1XX Controller Family
Inputs/outputs types and specifications

Output types

©
Danfoss | April 2018
Specifications (continued)
Description
Units
Input impedance
(5 V/GND)
Input impedance
(2.5 V)
Middle and low range DAFR
Input impedance
Input impedance
(5 V/GND)
Input impedance
(2.5 V)
If the frequency goes to zero, the data will not decay over time, it will be updated once a new pulse is
seen, or times out. It is possible to monitor the count of pulses to know when the frequency reading is
updated.
Digital (DOUT)
Digital/PVG valve reference power (DOUT/PVGpwr)
Pulse width modulated (PWM/DOUT/PVGOUT)
Output pins available on MC0XX-1XX Controller Family
PLUS+1
®
module
DOUT
(3 A)
MC012-110/112
MC024-110/112
MC024-120/122
MC050-110/112
3
MC050-120/122
6
MC050-155/15B
1
IOX012-110
IOX024-120
OX012-110
OX024-110
4
PLUS+1
®
modules feature user-configurable output pin parameters. Output pin parameters are
®
configured using PLUS+1
GUIDE templates.
W
Warning
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders.
The module will be powered up if battery voltage is applied to the module's output pin. To protect
against unintended movement, secure the machine.
C
Caution
Warranty will be voided if module is damaged.
Avoid significant current driven back through an output pin.
Minimum
Typical
12
6.64
91
12.7
6.86
DOUT/PVGpwr
(3 A)
3
2
2
Maximum
Comment
13.1
Pull up to +5 V or pull down
to ground.
7.02
Pull to +2.5 V.
175
No pull up or pull down.
14.0
Pull up to +5 V or pull down
to ground.
7.26
Pull to +2.5 V.
PWMOUT/DOUT/PVGOUT
(3 A)
2
4
8
10
6
2
2
8
6
10
L1321895 | BC00000227en-US0401 | 13