Technical Information
PLUS+1® MC0XX-1XX Controller Family
Inputs/outputs types and specifications
©
Danfoss | April 2018
Specifications (continued)
Description
Absolute accuracy of full range
Output settling time
PWM frequency
Dither frequency
Dither amplitude
Over-current trip point
Units
Minimum
% of full scale
ms
Hz
33
Hz
33
A
0
A
5
Maximum
Comment
3
1% typical. Offsets removed
when command is Ø.
100
Depends on load
characteristics.
4000
Some pins have a fixed
frequency, consult module
application program interface
(API).
250
Increased in steps, see module
API.
0.5
Increased in steps, see module
API.
5.25
There is over-current protection
built into each output driver. If
the instantaneous current
exceeds the trip point, the
driver is latched off. GUIDE
application software can reset
the latch and attempt to drive
current again.
L1321895 | BC00000227en-US0401 | 17