Dout And Dout/Pvgpwr - Danfoss PLUS+1 MC0XX-1 series Technical Information

Table of Contents

Advertisement

Technical Information
PLUS+1® MC0XX-1XX Controller Family
Inputs/outputs types and specifications
14 |
©
Danfoss | April 2018

DOUT and DOUT/PVGpwr

Digital (DOUT) and Digital/PVG Reference Power (DOUT/PVGpwr).
Digital outputs can source up to 3 A
Only MC050-110, MC050-120, and OX024-110 modules have DOUT.
DOUT and DOUT/PVG Pwr pins are pair limited and a function of temperature.
Output per pair is: 6 A maximum at 25° C [77° F]. Output per pair is 4 A maximum at 70° C [158˚ F]
MC050-110 pairs are: C1p31 and C1p32, C1p33 and C1p34, C1p35 and C1p36
MC050-120 pairs are: C1p33 and C1p34, C1p35 and C1p36, C1p37 and C1p38, C1p39 and C1p40
OX024-110 pairs are: C1p6 and C1p7, C1p8 and C1p9, C1p10 and C1p11
Example: at a module temperature of 70˚ C [158˚ F], if C1p31 is sourcing 2.5 A, the most current that
can be sourced on its paired pin C1p32 is 1.5 A
C
Caution
Driving an inductance with higher turn off energy, than shown in the graph
Demagnetization Energy at 150 C
adding an external recirculation diode or driving with a PWM output.
General
Description
Configuration
Type
Short circuit to ground protection
Open circuit detection
Parallel operation
Shut off
Specifications
Description
Allowed voltage at pin
Output voltage, energized state V
Output voltage, off state
Output current range for a
status bit to read OK
Do not connect a digital output to battery+ (back drive) without a series diode.
on page 15, may cause damage to the device. This can be avoided by
Comment
Sourcing only.
Linear switching.
Non-damage, current/thermal limit with status indication;
automatic latch off /resume.
Fault indication provided. The GUIDE Pin Status requires a load of
500 mA to be connected or an open fault will be declared.
Digital outputs from the same module are capable of being
connected together such that the net current rating is the sum of
the individual ratings; timing is resolved by the operating system;
diagnostic capability is maintained.
Processor control with hardware WatchDog override.
Units
Minimum
V
0
Vbatt-1.0
V
0
A
0.5
Single Pulse Maximum
Maximum
Comment
36
See
Caution statement
Vbatt
Over all load conditions.
0.1
At Rload=200 Ω
3
See
note regarding pair
L1321895 | BC00000227en-US0401

Hide quick links:

Advertisement

Table of Contents
loading