Screw the bulkhead assembly onto the threaded
connector temporarily. Mark the position of the
two fixing holes (Fig.28) securing the bulkhead
to the wall.
Note: If screw thread protrudes too far out of
the wall, it can be cut to the correct length using
a hacksaw.
Unscrew and remove the bulkhead assembly.
Check the location of the pipe in the wall before
drilling.
Drill and plug the wall.
(An appropriate drill bit should be used. If the
wall is brick, plasterboard or a soft building block,
appropriate wall plugs and screws should be fitted).
If fitting to a hollow wall structure, it may be
preferable to secure the bulkhead by applying a
bead of silicon seal to the back of the bulkhead.
Apply PTFE tape to the threaded connector.
Screw the bulkhead assembly onto the threaded
connector until tight to the wall and the two
fixing holes are aligned. Secure to the wall with
the two screws supplied (Fig.29).
Finish by clipping the cover onto the bulkhead
making sure the protruding legs locate in the
bulkhead body.