Triton T300si Installation And Operating Instructions Manual

Triton T300si Installation And Operating Instructions Manual

Wireless remote electric shower

Advertisement

T300si wireless
remote
electric shower
Installation and
operating
instructions
I
nstallers please note these InstructIons are to be left wIth the user
2180520B
June 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T300si and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Triton T300si

  • Page 1 T300si wireless remote electric shower Installation and operating instructions nstallers please note these InstructIons are to be left wIth the user 2180520B June 2006...
  • Page 2: Table Of Contents

    T300si wireless remote electric shower ConTenTs Page Important safety information Introduction Specifications Advice to users Key to main components 4 – 5 Electrical requirements 6 – 7 Battery safety guidelines 8 – 9 Water requirements Installation options 11 – 12 Siting of the shower 13 –...
  • Page 3: Important Safety Information

     Products manufactured by Triton are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations.  WarnIng: Do not operate shower if frozen, or suspected of being frozen. It must thaw out before using.
  • Page 4: Introduction

    T300si wireless remote electric shower inTroDuCTion sPeCifiCaTions This book contains all the necessary fitting and Electrical operating instructions for your Triton T300si nominal power nominal power wireless remote electric shower — please read rating at 240V rating at 230V them carefully.
  • Page 5: Advice To Users

    T300si wireless remote electric shower aDViCe To users ElEctromagnEtIc compatIbIlIty The following points will help you understand this product is intended for domestic how the shower operates: use. a. The electric heating elements operate at a This product may temporarily be affected constant rate at your chosen power setting.
  • Page 6: Key To Main Components

    T300si wireless remote electric shower KeY To main ComPonenTs Fig. Remote pack (fig.1) 1. Top cable entry 2. Bottom pipe entry 3. Rear pipe entry area 4. Rear cable entry area 5. Wall screw fixing 6. Terminal block 7. Printed circuit board 8.
  • Page 7 T300si wireless remote electric shower KeY To main ComPonenTs Fig. Riser rail contents (fig.3) 22. Showerhead holder 23. Bridging wall bracket (lug on inside) 24. Guide bracket (no lugs inside) 25. Bottom bracket 26. Bracket trim ring (3 off) 27. Bracket end trim (3 off) 28.
  • Page 8: Electrical Requirements

    T300si wireless remote electric shower eleCTriCal requiremenTs 1.1 The electrical rating of the shower is shown on the rating label (Fig.) within the unit. WarnIng! Before making any sort of electrical connection within the installation, make thIs applIancE must bE sure that no terminal is live.
  • Page 9 T300si wireless remote electric shower parts of other appliances and services the cord of a cord operated switch, and in the room in which the shower is to should be placed so that it is not possible be installed, to conform to current IEE to touch the switch body while standing regulations.
  • Page 10: Battery Safety Guidelines

    T300si wireless remote electric shower baTTerY safeTY GuiDelines alWays Used correctly, domestic batteries are a safe and dependable source of portable power. Problems can occur if they are misused or abused — resulting in leakage or, in extreme cases, fire or explosion.
  • Page 11 T300si wireless remote electric shower nEVEr alWays never attempt to recharge ordinary batteries, Supervise children if they are replacing batteries either in a charger or by applying heat to them. themselves in order to ensure these guidelines There are special rechargeable batteries which are followed.
  • Page 12: Water Requirements

    T300si wireless remote electric shower WaTer requiremenTs Fig. Diagrammatic view (not to scale) The installation must be in accordance with Water Regulations/Bylaws. To ensure activation Mains electric supply of the heating elements, the shower must be (via double pole switch) connected to a mains water supply with a minimum running pressure of 100 kPa (1.0 bar)
  • Page 13: Installation Options

    T300si wireless remote electric shower insTallaTion oPTions Fig. Bulkhead fitting bulkhead fitting The control panel is installed onto a tiled wall. The remote pack is behind an adjoining wall with heated water pipe running to bulkhead (Fig.). Stand-alone riser rail assembly.
  • Page 14 T300si wireless remote electric shower Fig. Through the ceiling fitting (short) Fig.0 Through the ceiling fitting (long) Ceiling trim Guide bracket Ceiling trim Bridging bracket Showerhead holder Bridging bracket Control panel Showerhead holder Control panel Bottom bracket Bottom bracket...
  • Page 15: Siting Of The Shower

    T300si wireless remote electric shower siTinG of THe sHoWer Fig. WarnIng! Control the shower must not be positioned panel where it will be subjected to freezing conditions. Height of Important: If installing onto a tiled wall Bulkhead can sprayhead be mounted either...
  • Page 16 T300si wireless remote electric shower Pressure relief safety device Fig. A pressure relief device (PRD) is designed into the shower unit which complies with European outlet standards. The PRD (Fig.) provides a level of appliance protection should an excessive build up of pressure occur within the shower.
  • Page 17: Installation Option 1: Bulkhead Fitting

    T300si wireless remote electric shower insTallaTion oPTion 1: bulKHeaD fiTTinG Heated water pipe in the wall Fig. Decide on the position of the control panel, the bulkhead fitting and riser rail within the showering area. Establish a route in the wall between the remote pack and the outlet bulkhead.
  • Page 18 T300si wireless remote electric shower Procedure Fig. Unscrew the top and bottom retaining screws (Fig.) and lift cover from the backplate. To allow access to the pipe and cable connections, remove the two screws (Fig.) and take off the trimplate.
  • Page 19: Plumbing Connections

    T300si wireless remote electric shower PlumbinG ConneCTions Fig. Plumbing to be carried out before wiring. DO nOT use jointing compounds on any pipe Bottom View fittings for the installation. DO nOT solder fittings near the shower unit as remove heat can transfer along pipework and damage components.
  • Page 20 T300si wireless remote electric shower make sure the backplate is square on the wall Fig. and tighten the two retaining screws which hold Copper it to the wall. pipe Turn on the mains water supply and check for leaks in the pipework connection to the remote Grab ring pack.
  • Page 21 T300si wireless remote electric shower note: Check the correct tubes have been used Fig. as they are similar in diameter and length (the PRD tube is clear). outlet Important: Do not bend either the PRD tube or heated water pipe sharply as they will kink and restrict the water flow.
  • Page 22: Fitting The Bulkhead

    T300si wireless remote electric shower fiTTinG THe bulKHeaD Fig. Route the heated water pipe to the outlet position and push on the fittings as shown in Heated water Fig.. Connect the heated water pipe to a pipe ½” BSP x 15mm female thread elbow or straight coupler compression fitting (Fig.).
  • Page 23 T300si wireless remote electric shower Apply PTFE tape to the threaded connector. Fig. Screw the bulkhead assembly onto the threaded connector until tight to the wall and the two fixing holes are aligned. Secure to the wall with the two screws supplied (Fig.).
  • Page 24: Fitting The Riser Rail

    T300si wireless remote electric shower fiTTinG THe riser rail Fig.0 WarnIng! the edges of the riser rail are extremely sharp. take care when handling and cutting the rails. Decide the position for the rail on the wall within the shower area. Proceed as follows: Offer the bottom bracket to the wall and mark the centre hole.
  • Page 25: Fitting The Hose And Showerhead

    T300si wireless remote electric shower Fit the blanking plug into the base of the bottom Fig. bracket and secure with the retaining clip (Fig.). Place a bracket trim onto the end of each bracket (Fig.) and then insert the riser rail trim into the top of the riser rail assembly (Fig.).
  • Page 26: Installation Option 2: Fitting Through The Ceiling

    T300si wireless remote electric shower insTallaTion oPTion 2: fiTTinG THrouGH THe CeilinG Heated water pipe routed inside the riser Fig.0 rail Riser rail long enough to WarnIng! clear ceiling joists, etc. check there are no hidden cables or pipes before drilling holes for wall plugs.
  • Page 27: Fitting The Ceiling Riser Rail

    T300si wireless remote electric shower fiTTinG THe CeilinG riser rail Fig. WarnIng! the edges of the riser rail are extremely sharp. take care when handling and cutting the rails. note: There are two lengths of riser rail supplied to cater for differing ceiling heights. It may be necessary to shorten the 940mm riser rail using a suitable hacksaw or pipe cutter.
  • Page 28 T300si wireless remote electric shower Cut the riser rail to length. If required, use the Fig. guide bracket for additional support. Slide the trim ring onto the bridging bracket. Fit the upper riser rail into the top of the bridging bracket, making sure the cut-out engages the bracket lug.
  • Page 29: Fitting The Remote Pack

    T300si wireless remote electric shower fiTTinG THe remoTe PaCK Fig. WarnIng! the remote pack must not be positioned where it will be subjected to freezing conditions. Important: the remote pack must be mounted on a flat surface. It is important...
  • Page 30 T300si wireless remote electric shower note: Deviations from the designated entry Fig. points will invalidate product approvals. If a bottom surface entry is required for the Bottom View mains cold water then the necessary hole will need to be cut out in the trimplate and cover remove (Fig.).
  • Page 31: Plumbing Connections

    T300si wireless remote electric shower PlumbinG ConneCTions Fig. Plumbing to be carried out before wiring. DO nOT use jointing compounds on any pipe fittings for the installation. DO nOT solder fittings near the shower unit as heat can transfer along pipework and damage components.
  • Page 32 T300si wireless remote electric shower make sure the backplate is square on the wall Fig. and tighten the two retaining screws which hold it to the wall. Turn on the mains water supply and check for leaks in the pipework connection to the remote pack.
  • Page 33: Electrical Connections

    T300si wireless remote electric shower eleCTriCal ConneCTions Fig. SWItCh oFF the eleCtRICIty SUPPly At the MAInS. Fig. shows a schematic wiring diagram. The cable entry points are shown in Fig.. The cable can be surface clipped, hidden or via 20mm conduit.
  • Page 34: Fitting The Control Panel Bracket

    T300si wireless remote electric shower fiTTinG THe ConTrol Panel Fig. braCKeT Align the mounting bracket on the wall and mark the location of the four fixing holes. Drill and plug the wall. Using the screws supplied, secure the mounting bracket to the wall (Fig.).
  • Page 35: Associating The Shower Unit

    T300si wireless remote electric shower assoCiaTinG THe sHoWer uniT Fig. Before the shower can be used the control panel must be associated to the remote pack. This will link the control panel to the specific remote pack. note: This procedure should be carried out before fitting the control panel to the wall.
  • Page 36: Commissioning

    T300si wireless remote electric shower CommissioninG Fig. setting up the remote pack Press the START/STOP button. The ‘HIGH’ and ‘POWER On’ indicators will light for a few seconds and after a short delay water will begin to flow. It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris in the system is being flushed from the shower.
  • Page 37: Operating The Shower

    T300si wireless remote electric shower oPeraTinG THe sHoWer Fig. Important: Make sure the commissioning procedure has been carried out. Failure to do so will damage the unit and invalidate the guarantee. High power button To start the shower note: When first switched on at the isolation switch, the shower will attempt to initialise itself.
  • Page 38: Operating The Shower

    T300si wireless remote electric shower The lower button is for cold water only. Fig. Adjusting the temperature control at this setting will only change the force of the water from the showerhead (it will not alter the water temperature). To adjust the shower temperature...
  • Page 39: Operating Functions

    T300si wireless remote electric shower oPeraTinG funCTions Fig. low pressure indicator (fig.69) If this indicator flashes every half a second, it means the water pressure has fallen below the minimum required for correct operation of the shower, resulting in the low pressure cut- out operating.
  • Page 40: Continuous And Timed Operation

    T300si wireless remote electric shower safety cut-out Fig.0 The unit is fitted with a non-resettable over- temperature safety device. In the event of abnormal operation which could cause unsafe temperatures within the unit, the device will disconnect the heating elements. It will require a...
  • Page 41: Adjusting The Showerhead

    T300si wireless remote electric shower aDJusTinG THe sHoWerHeaD Fig. Fig. Five showerhead patterns are available (Fig.). Adjust the spray pattern by turning the bezel on the showerhead in either direction until the desired pattern is obtained.
  • Page 42: Cleaning

    T300si wireless remote electric shower CleaninG Fig. Before cleaning, turn off the unit at the isolation Sprayplate switch to avoid the shower being accidentally switched on. IT IS ImPORTAnT TO KEEP THE SHOWERHEAD CLEAn TO mAInTAIn THE PERFORmAnCE OF THE SHOWER. The hardness of the water will determine the frequency of cleaning.
  • Page 43: Instructions For Installers And Service Engineers Only

    T300si wireless remote electric shower insTruCTions for insTallers anD serViCe enGineers onlY CleaninG THe filTer Fig. It is recommended that the filter is periodically cleaned in order to maintain the performance of the shower. It is essential that this operation is carried out by a competent person.
  • Page 44: Spare Parts

    T300si wireless remote electric shower sPare ParTs ref. Description Part no. Terminal block 9.5kW 82200800 10.5kW 82200850 Transformer 22005020 Remote pack PCB 9.5kW 7072570 10.5kW 7072985 RF module 7073501 RF data cable P15310901 Thermal cut-out (main) 22009860 Heater can assembly 9.5kW...
  • Page 45: Spare Parts

    T300si wireless remote electric shower sPare ParTs ref. Description Part no. 20. Showerhead holder 83308410 21. Bridging bracket assembly (bracket, end trim & trim ring) 83309970 22 Bridging bracket 83309450 23. Guide bracket assembly (bracket, end trim & trim ring) 83309980 24.
  • Page 46: Fault Finding

    T300si wireless remote electric shower faulT finDinG Important: Switch oFF the electricity at the mains supply and remove the circuit fuse before attempting any fault finding inside the unit. Problem/symptom Cause action/cure 1 Shower 1.1 Interrupted power 1.1.1 Blown fuse or circuit breaker. Check supply.
  • Page 47: Fault Finding

    T300si wireless remote electric shower faulT finDinG Problem/symptom Cause action/cure 5 Cold indicator 5.1 Purge pin not placed 5.1.1 Isolate the electricity supply. Remove light on and low correctly. remote pack cover and place purge pin on one pin pressure indicator only.
  • Page 48: Service Policy

     Triton Customer Service will be able to confirm Any part found to be defective during this whether the fault can be rectified by either the...