Triton T300si Installation And Operating Instructions Manual page 21

Wireless remote electric shower
Table of Contents

Advertisement

Fit the clear plastic PRD tube through the can
outlet pipe boss situated at the rear of the outlet
pipe (Fig.24) and push firmly on to the PRD
outlet.
The other end of the PRD tube needs to be
directed to a suitable and visible waste – see P14
'Pressure relief safety device' for further details.
Note: Check the correct tubes have been used
as they are similar in diameter and length (the
PRD tube is clear).
IMPORTANT: Do not bend either the PRD
tube or heated water pipe sharply as they
will kink and restrict the water flow. If a
tight bend is required in the heated water
pipe cut the pipe and rejoin with standard
10 mm elbow compression fittings or push-fit
connectors.
Insert a 25 mm length of 8 mm copper pipe
(four are supplied, but more may be required)
to provide support for the plastic pipe under the
olive ring. If possible, the connections should be
accessible so that adjustment can be carried out
when required.
T300si wireless remote electric shower
19
Can
PRD
outlet
Pipe
boss
Outlet
pipe
PRD tube
Fig.24