27 Group Monitoring Parameter - Veikong VFD500 Series Operation Manual

High performance vector and torque
Hide thumbs Also See for VFD500 Series:
Table of Contents

Advertisement

Chapter 5 Function code table
Running
r27.00
frequency
r27.01
Set frequency
Direction
r27.02
indicator
r27.03
Bus voltage
VF separation
r27.04
setting
r27.05
Output voltage
r27.06
Output current
Output current
r27.07
percentage
r27.08
Output torque
r27.09
Torque setting
Drives running
r27.10
mode status 1
Drives running
r27.11
mode2
VFD500 high performance vector control frequency inverter user manual

27 Group Monitoring parameter

It can set unit as per Parameter P21.07
It can set unit as per Parameter P21.07
bit0:direction of running frequency
bit1:direction of setting frequency
bit2:direction of main frequency
bit3:direction of auxiliary frequency
bit4:direction of UpDown offset
bit5 reserved
Unit:1V
unit:0.1%
unit:0.1V
unit:0.1A
unit:0.1%(100% of motor rated current)
0.1%
0.1%
Bit0:Running status 0-Stop;1-Run
Bit1:Motor direction0-Forward;1-Reverse
Bit2:Ready signal:0-not ready;1-ready
Bit3:fault status 0-no fault;1-fault
Bit4~5:fault type:0-free stop;1-fast
stop;2-stop as per stop mode;3:continue to
run
Bit6:jog status:0-no jog;1-jog status
Bit7:Auto tune :0-no;1-yes
Bit8:DC braking:0-Non DC braking;1-DC
braking
Bit9:Reserved
Bit10~11:Acceleration and Deceleration:
0:stop/zero output;1:speed up;2:slow
down;3:constant speed
Bit12:reserved
Bit13:current limit status:0-no;1-yes
Bit14:overvoltage stalladjustment:0-no ;1-yes
Bit15:undervoltage stall
adjustment :0-no;1-yes
Bit0~1:current command
source:0-keypad;1-terminal ;2-communicatoi
n
Bit2~3:motor option:0-motor 1;1-motor 2
Bit4~5:current motor
control:0-VF;1-SVC;2-VC
- 71-
-
-
-
-
-
-
-
-
-
-
-
-