00Group Basic Function - Veikong VFD500 Series Operation Manual

High performance vector and torque
Hide thumbs Also See for VFD500 Series:
Table of Contents

Advertisement

VFD500 high performance vector control frequency inverter user manual
Function
Parameter name
code
P00.00
User password
P00.01
Access authority
Parametercopy
P00.02
andbackup
P00.03
RESET
P00.04
Motor Control mode
Description

00Group Basic Function

0 ~ 65535
No user password status (P00.01 = 1
after power-on):
Entering the same non-zero value twice in
succession sets a user password and enters
lockout.
password lock state:
Enter the password to enter the unlock state.
unlocked state:
Enter the original password to enter the lock
state; enter the same value twice in a row to
change the password (clear the password if
you enter 0 twice in a row).
0:END USER
Some parameter are not authorized to check
when user password in locked state 1:
Standard
ALL Parameter can be checked
0:No action
11:save all parameter to EEPROM backup
space
12:Restore all parameter from EEPROM
backup space
13:Parameter upload to LCD VFD500
(excluded for motor parameter and auto
tune related parameter)
14: Parameter upload to LCD VFD500
(All parameter except for factory data)
0:NO ACTION
11: Restore default parameter except for motor
parameter and auto-tune related parameter
and factory parameter
12:Restore default to factory parameter
13:Clear tripping record
0:VF
1:SVC(sensorless vector control)
Open loop vector and torque
controlwithout encoder feedback
2:VC Vector control with sensor
Close loop vec tor and torque control
supporting encoder feedback in high
precision or torque control application
- 28 -
Chapter 5 function code table
Default
Property
0
1
0
0
0

Hide quick links:

Advertisement

Table of Contents
loading