NOTE: THE SUPPLY LINE FROM THE ENGINE WILL BE HOOKED TO
THE DRIVERS SIDE HOSE.
Locate in the Hardware Sack Kit the Water Valve and (4) worm gear
clamps.
Attach the water valve to the passenger side hose. Use the worm gear
clamps supplied.
Cut the supply hose from the engine and attach it to the hose splice on
the drivers side heater hose. Use the worm gear clamps supplied.
Locate the Temperature Control Cable and attach it to the water valve
as shown. Set the cable so that the Temp knob is pushed all the way in
and the water valve is in its fully closed position.
Locate the electrical plug that attaches to the Pressure switch on the
drier
There are two white wires attached to the pressure switch, route one of
them to the compressor clutch and attach a Female bullet connector.
The other wire route along the Liquid hose and attach
to clutch wire at the firewall. Secure wires with tywraps provided.
Use the same refrigeration tape to seal around the cable and clutch
wire.
Reinstall and reconnect the battery.