Aborting Jogging
Aborting is a process with which the otherwise normal sequence of a target
approach is not carried out (see Chapter 2.2)
"Jogging" is aborted when:
Speeds
With the FM 351 jogging is possible at two speeds:
You specify the speed on calling the operating mode either in the parameter-
ization interface or in the FC JOG_MOD.
Limit for a Linear
The limits for the Jogging operating mode differ for a synchronized and a
Axis
non-synchronized axis.
Table 9-1

Jogging with a Synchronized and Non-Synchronized Axis

Axis is Not Synchronized
If the traverse range limit is crossed during jogging:
The actual value display jumps to the opposite limit
and
The positioning is aborted.
–1000 m
1000 m
1
Switchover difference positive
FM 351 Positioning Function Module
EWA 4NEB 720 6001-02
The signal Drive enable is deleted.
A traverse range limit is crossed with a linear axis.
Jogging at rapid speed.
Jogging at creep speed.
Jogging is positioning to target positions which are lo-
cated at a distance of the half target range from the soft-
ware limit switches.
The limits are determined from:
SLE–
linear axis
SLS+
linear axis.
If you do not previously release the key, the FM 351
terminates at a target point which is located at the half
target range in front of the corresponding software limit
switch. All ranges, which are necessary for correct ter-
mination, are set by the FM 351 at this target point.
Part of the working range in which no target position
may be located.
2
Switch-off difference positive
Operating Modes and Settings
Axis is Synchronized
1
/
target range for the positive end of the
2
1
/
target range for the negative end of the
2
Maximum target
3
target range
9
SLE
3
2
1
9-5