Siemens SIMATIC FM 351 Installation Manual page 80

Positioning function module
Hide thumbs Also See for SIMATIC FM 351:
Table of Contents

Advertisement

Programming the FM 351
Input
5.6
5.7
Marker
6
6-34
Marker
Description
5.6
Delete interrupt display
5.7
Delete error display
The table gives a brief overview of the memory markers used.
Marker
M 31.0
Write function running
M 31.1
Edge trigger flag for write initiation
M 31.2
Start parameter for write function
M 31.3
Data transfer for write function running
M 31.4
Data error
M 32.0
Set reference point running
M 32.1
Do not evaluate enable input (single setting)
M 32.2
Evaluate enable input (single setting)
M 32.3
Delete residual distance (single command)
M 32.4
Transfer Increment 254
M 32.5
Transfer Increment 255
M 36.0
Start edge trigger marker
M 36.1
Edge trigger marker, positive direction
M 36.2
Edge trigger marker, negative direction
M 36.4
Parameter START mode block
M 36.5
Parameter DIR_P mode block
M 36.6
Parameter DIR_M mode block
M 41.0
Read function running
M 41.2
Start parameter for read function
MB 20
Increment number
MB 28
Mode selection
MB 30
Write function selection (settings, single settings)
MW 0
Replica, Input Word 1
MW 4
Replica, Input Word 2
MW 8
Replica, Output Word 1
MW 12
Replica, Output Word 2
MW 34
Error code for write function
MW 44
Error code for read function
Output
Marker
Description
FM 351 Positioning Function Module
Description
EWA 4NEB 720 6001-02