Control System - Lenze MOBILE DCU Hardware Manual

Hide thumbs Also See for MOBILE DCU:
Table of Contents

Advertisement

5
Installation
Connections of MOBILE DCU, PSU, DCU PSU

Control system

5.6.6
Control system
X31
58
1
CAN_H_TERM_PUBLIC
20
2
CAN_H_PUBLIC
14
8
3
CAN_L_PUBLIC
1
4
InterLock2
5
CAN_L_PRIVATE
6
CAN_H_PRIVATE
7
InterLock1
8
TRM15
9
CAN_H_PUBLIC
10
CAN_L_PUBLIC
11
CAN_L_TERM_PUBLIC
12
ID_PIN1
13
ID_PIN3
14
FLX_IN4
15
FLX_IN3
16
FLX_IN2
17
FLX_IN1
18
ID_PIN2
19
ID_PIN4
20
TRM31
21
TRM30
22
TRM30
23
FLX_OUT4
24
FLX_OUT3
25
FLX_OUT2
EMDAG020c
26
FLX_OUT1
Ò
Description
Public CAN, bus termination CAN−High
Public CAN In
Potential−free output, connection 2
Private CAN
Potential−free output, connection 1
Switch on/off device
Public CAN Out
Public CAN, bus termination CAN−Low
Address offset for setting the CAN address
Digital inputs
l
Can also be parameterised as frequency inputs
Digital inputs
l
Can also be parameterised as analog inputs
Address offset for setting the CAN address
Vehicle mass, negative pole of the vehicle battery
Supply voltage for control electronics
Digital outputs
EDSMDAG EN 2.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents