Parameter Reference; Communication-Relevant Parameters Of The Operating System - Lenze POWERLINK E84DGFCL Series Communications Manual

Communication unit for inverter drives 8400 motec
Table of Contents

Advertisement

Parameter reference

Communication-relevant parameters of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11
Parameter reference
This chapter complements the parameter list and the table of attributes in the software manual and
the »Engineer« online help for the Inverter Drive 8400 motec by the parameters for POWERLINK
communication.
11.1
Communication-relevant parameters of the operating system
Reference manual/online help for the Inverter Drive 8400 motec.
Here you will find general information on parameters.
This chapter lists the communication-relevant parameters of the inverter operating system in nu-
merically ascending order.
C01501
Parameter | Name:
C01501 | Resp. to communication error with MCI
Configuration of monitoring functions for the Communication Unit
Selection list
Subcodes
C01501/1
C01501/2
 Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT
C01503
Parameter | Name:
C01503 | MCI timeout
Setting range
0
Subcodes
C01503/1
 Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT
Lenze · Decentralised frequency inverter 8400 motec (POWERLINK Option) · EDS84DMOTPL EN 1.0 - 11/2018
0 No response
1 Error
4 Warning Locked
Lenze setting
1: No Response
1: No Response
(min. value | unit | max. value)
ms
Lenze setting
200 ms
Info
Resp. to MCI fault 1
• Response to a communication fault.
Resp. to MCI fault 2
• Response to a fault in the Communication Unit.
Scaling factor: 1
1000
Info
MCI timeout
Scaling factor: 1
Data type: UNSIGNED_8
Index: 23074
= 5A22
d
h
Data type: UNSIGNED_16
Index: 23072
= 5A20
d
h
45