Download Print this page

Technical Specifications - BEA LZR-WIDESCAN Manual

Motion, presence, and safety sensor for industrial doors
Hide thumbs Also See for LZR-WIDESCAN:

Advertisement

TECHNICAL SPECIFICATIONS

Technology
Detection mode
Max. detection field
Thickness of first curtain
Typ. mounting height
Min. reflectivity factor
Typ. min. object size
Testbody
Emission characteristics
Supply voltage
Power consumption
Response time
Output
Input
LED signals
Dimensions
Material / Color
Rotation angles on bracket
Tilt angles on bracket
Protection degree
Temperature range
Vibrations
Norm conformity
Specifications are subject to change without prior notice. All values measured in specific conditions.
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107).
Verify that all appropriate industry signage and warning labels are in place.
General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.BEAinc.com
Page 16 of 16
Page 16 of 16
Page 16 of 16
Page 16 of 16
LASER scanner, time-of-flight measurement (7 laser curtains)
Motion and presence
Width: 1 x mounting height
Depth: 1.2 x mounting height
inch per 3 feet of mounting height
3
4
6'6" – 19'6"
> 2 % (of floor and object) (measured at max. 19'6" in safety field)
6" @ 19'6" (in proportion to object distance)
27
" × 11
1
3
2
4
IR LASER: Wavelength 905 nm, max. output pulse power 25 W, Class 1
Visible LASER: Wavelength 650 nm, max. output CW power 3 mW, Class 3R
12 – 24 VAC ±10%
< 2.5 W (heating: off)
Typ. 100 ms (max. 500 ms)
2 solid-state relays ( galvanic isolation, polarity free )
30 VDC (max. switching voltage) – 100 mA (max. switching current)
- in switching mode: NO/NC
- in frequency mode: pulsed signal (f= 100 Hz ±10%)
1 electro-mechanic relay (galvanic isolation, polarity free)
42 VAC (max. switching voltage) – 500 mA (max. switching current)
30 VDC (max. switching voltage)
low < 1 V
2 tri-colored LED: Output status / remote control response / error signals
7
" (H) x 6" (W) x 4" (D) (approx.)
3
4
PC/ASA / Black
45° to the right, 15° to the left ( lockable )
-10 – 5°
NEMA 4 / IP65
-22 – 140 °F
< 2 G
EN 61000-6-2
EN 61000-6-3
EN 60950-1
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
"× 7
"
3
4
12 – 30 VDC ±10% @ sensor terminal
< 15 W (heating: eco or auto)
high > 10 V (voltage threshold)
EN 60825-1
EN ISO 13849-1 Pl "d"/ CAT2
EN 62061 SIL 2
adjustable, depending on user settings
EN 61496-1 ESPE Type 2
EN 12978
EN 50581
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821

Advertisement

loading