OPTIONAL REMOTE CONTROL SETTINGS (cont.)
When programming each of the parameters listed below (function,
logic, holdtime), you must always enter 3 digits for the given parameter
(output 1, output 2, relay).
1st digit = Output 1
2nd digit = Output 2
3rd digit = Relay
If you do not want to change the setting of an output, select 0.
First, assign the outputs.
Out 1 Function*
Out 2 Function*
Relay Function*
Next, determine the desired states and hold times for each output chosen above.
Out 1 Logic**
Out 2 Logic**
Relay Logic**
Out 1 Holdtime
Out 2 Holdtime
Relay Holdtime
...
MOTION
Direction
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
motion or
no change
motion
pull-cord
motion or
no change
motion
pull-cord
motion or
no change
motion
pull-cord
passive
active
100 ms
1 s
100 ms
1 s
100 ms
1 s
UNI 100%
ANY
DEFAULT
1
ANY
2
UNI 100% (default)
6
UNI REV
7
UNI 100% +
9
UNIDIRECTIONAL
presence
safety
presence
safety
presence
safety
NO
NC
NO
NC
3 s
5 s
10 s
3 s
5 s
10 s
3 s
5 s
10 s
UNI REV
detection in any direction
unidirectional detection (approaching within the width of
the max. field)
unidirectional detection reverse (going away)
unidirectional detection (approaching within the width of
max. field + 1 m of bidirectional detection in front of door)
unidirectional detection (approaching in any direction;
distance between object and sensor decreases)
FOR EXAMPLE, if you want the
outputs to be Motion (Output 1), Pull-
Cord (Output 2), and Safety (relay),
you must push the following buttons
in the following order:
motion +
motion +
pull-cord
speed
height
motion +
presence
pull-cord
speed
+ height
motion +
motion +
pull-cord
speed
height
** Output status during non-detection.
30 s
1 min
5 min
30 s
1 min
5 min
30 s
1 min
5 min
UNI 100%+
motion
motion
pull-cord
pull-cord
safety
presence
motion
motion
pull-cord
pull-cord
safety
presence
motion
motion
pull-cord
pull-cord
safety
presence
10 min
20 min
10 min
20 min
10 min
20 min
UNIDIRECTIONAL
Page 11 of 16