Download Print this page

Troubleshooting - BEA LZR-WIDESCAN Manual

Motion, presence, and safety sensor for industrial doors
Hide thumbs Also See for LZR-WIDESCAN:

Advertisement

TROUBLESHOOTING

E1: CPU-XXX
E1
1
E2: XXX PWR
E2
2
E2: IN SUPPLY
E2: TEMP
E5
5
INSTALL
E5: FLATNESS
E5: TILT
E5: AZIMUTH
E5: HEIGHT
E5: TIME-OUT
E6: FQ OUT
E6
6
E8: ...
E8
8
ORANGLE LED is on
LED and LCD display
are off
Door does not react
Product does not
1
2
3
A
4
5
6
B
7
8
9
C
F1
0
F2
D
react to remote
control
Motion detection
starts too late
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
The sensor encounters an internal
problem
The internal power supply is faulty
The power supply is too low or
too high
The internal temperature is too
low or too high
The sensor requests a teach-in
Faulty teach-in
Faulty teach-in due to tilt angle
Faulty teach-in due to lateral
angle
Faulty teach-in due to mounting
height
Faulty teach-in
Faulty sensor output 1
Faulty detection engine
The sensor encounters a memory
problem
Incorrect wiring
Service mode is activated
Sensor is password-protected
Negative angle is too large
Replace sensor.
Replace sensor
Verify power supply (Diagnostics > LCD).
Verify the sensor temperature (Diagnostics
>LCD).
Protect the sensor from direct exposure to
heat or cold.
Launch teach-in after angle adjustment.
All presence/safety outputs are activated.
Make sure that the teach-in zone is clear
of objects and then launch install teach-in.
Adjust tilt angle (max. 15° > Diagnostics
> LCD).
Launch install teach-in.
Adjust lateral angle (max. 45° >
Diagnostics > LCD).
Launch install teach-in.
Adjust mounting height
(max. 19'6", min. 6'6").
Launch install teach-in.
Relaunch install teach-in. Make sure that
there is no motion detection during at
least 5 seconds when LED starts flashing
red/green.
Slightly change your position and relaunch
an install teach-in.
Replace sensor.
If internal temperature is lower than
68 °F, wait until the heating process is
completed.
If temperature is higher than -4 °F, replace
the sensor.
Replace sensor.
Check wiring.
Check for damaged pins or sensor
harness.
Exit service mode (see page 10).
Enter correct password. If you forgot
the code, cut and restore power supply
in order to access the sensor without
entering a password during 1 minute.
Reduce angle of the sensor.
Page 15 of 16
Page 15 of 16
Page 15 of 16
Page 15 of 16

Advertisement

loading