Download Print this page

BEA LZR-WIDESCAN Manual page 14

Motion, presence, and safety sensor for industrial doors
Hide thumbs Also See for LZR-WIDESCAN:

Advertisement

TEACH-IN: WALK
You can also reshape one or more detection fields by walking around the requested field (steps 1 – 3). It is possible
to cut into the existing field from the border or to extract a field within the detection field (step 4).
Make sure the field is larger than desired.
The existing field size can be reduced and adapted, but cannot exceed the configured size.
1
LAUNCH A WALK TEACH-IN
Choose the desired field(s) by LCD or remote control:
Quick Start > TeachIn > Walk All: Motion, Presence, and Safety field
Quick Start > TeachIn > Walk Motion: Motion field only
Quick Start > TeachIn > Walk Presence: Presence field only
Quick Start > TeachIn > Walk Safety: Safety field only
2
GO TO STARTING POINT
Step away from the detection field and remove any objects (ladder, tools etc).
Go to the starting position of your detection field (see 1st picture below).
The delay after which the teach-in is launched is 60 seconds by LCD (adjustable to 30 or 120 sec via
Quick Start > More > TeachInDelay). The delay by remote control is 5 seconds.
3
DO NOT MOVE
The sensor learns its background as long as the LED flashes red-green.
4
START WALKING
When LED flashes green, hold one arm in the air and slowly start walking the
trace of the desired field shape. Then, stop and wait until LED stops flashing.
The teach-in was either successful or not (see TROUBLESHOOTING).
ADD TRACE / INVERT FIELD:
Using the remote control, you can add a trace of the field shape to all fields or one in particular (1, above).
You can invert each detection field (i.e. make the inactive side of the walked trace active) via LCD (Motion/Presence/Safety >
More > Field inversion) or remote control (see page 10). See image to right for inversion of the field pictured above (bottom
right). This feature is only available after a walk teach-in; standard setting will not allow for field inversion.
Always verify the field dimensions via the Field Display option on the LCD screen (Diagnostics > FieldDisplay).
To delete a trace, simply relaunch a walk teach-in and clear the respective detection zone for 15 seconds.
Page 14 of 16
Page 14 of 16
Page 14 of 16
Page 14 of 16
LEFT LED
...
....
..
60 SEC / 5 SEC
START outside of the
max. detection field.
STOP outside the max.
detection field.
START anywhere in the
max. detection field.
STOP close to the
starting point.
OR
OR
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
75.5916.03 LZR-WIDESCAN 20180821
Max field
Walk field
Max field
Walk field
5
...
....
..

Advertisement

loading