BEA LZR RS300 User Manual
BEA LZR RS300 User Manual

BEA LZR RS300 User Manual

Safety sensor for external railway doors

Advertisement

Quick Links

This user's guide is an informative document and
can not be seen as a commitment of result.
LZR
- RS300
®
SAFETY SENSOR
FOR EXTERNAL RAILWAY DOORS
User's Guide
for product version 0700 and more
1

Advertisement

Table of Contents
loading

Summary of Contents for BEA LZR RS300

  • Page 1 - RS300 ® SAFETY SENSOR FOR EXTERNAL RAILWAY DOORS User’s Guide for product version 0700 and more This user’s guide is an informative document and can not be seen as a commitment of result.
  • Page 3 SAFETY SENSOR FOR EXTERNAL RAILWAY DOORS Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer. The manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor. DESCRIPTION laser sweep emission protection cover laser sweep reception...
  • Page 4: Installation And Maintenance

    SAFETY The device emits invisible IR and visible laser radiations. IR laser: wavelength 905nm; output power 0.10mW (Class 1 according to IEC 60825-1) Visible laser: wavelength 635nm; output power 0.95mW (Class 2 according to IEC 60825-1) The visible laser beams are inactive during normal functioning. Do not stare into the visible red laser beams.
  • Page 5: Installation Steps

    APPLICATIONS CURVED DOORS - 4 curtains FLAT DOORS - 1 curtain INSTALLATION STEPS MOUNTING Use the adhesive Drill 4 holes as indicated Pass the cable +/- 10 cm Position the bracket mounting template on the mounting though the cable opening. and fasten the 4 screws to position the sensor template.
  • Page 6 WIRING GREEN POWER SUPPLY + POWER SUPPLY - BROWN WHITE RELAY 1 - NOT USED YELLOW PINK RELAY 2 - SAFETY FIELD GREY TEST - NOT USED BLUE POSITIONING Unlock the sensor and activate the visible laser beams. The visible laser beams indicate approximately the postion of the first curtain and limit the angle of the detection field.
  • Page 7 MOUNTING SIDE Select the corresponding mounting side. The sensor then learns its environment and automatically Stay outside of the detection field determines the detection field(s). Both red LEDs flash slowly and to avoid disturbances. the 3 visible laser beams automatically light up during 30 seconds. right left right...
  • Page 8 REMOTE CONTROL ADJUSTMENTS (OPTIONAL) FIELD WIDTH no safety field 0.5 m FIELD HEIGHT 0.5 m DETECTION CURTAINS CURTAIN deactivate curtain C1 + C2 are deactivated activate curtain C3 + C4 are active Only C1 is active. The distances between the curtains depend on the mounting height and side. When mounted on the left, the distance between the first and the last curtain is approximately 10 cm for every meter (mounting height).
  • Page 9: How To Use The Remote Control

    HOW TO USE THE REMOTE CONTROL After unlocking, the red If the red LED flashes quickly after unlocking, you To end an adjustment session, LED flashes and the sensor need to enter an access code from 1 to 4 digits. always lock the sensor.
  • Page 10: Troubleshooting

    TROUBLESHOOTING There is no power. No blue LED Check cable and connexion. The polarity of the power Check the polarity of the power supply. supply is inverted. Check the size of the fields. The detection LED The detection field is too remains green.
  • Page 11: Technical Specifications

    TECHNICAL SPECIFICATIONS Technology: laser scanner, time-of-flight measurement Detection mode: motion and presence Detection range: 5 m x 5 m @ 2% remission factor Remission factor: > 2 % Angular resolution: 0,3516 ° Min. detected object size (typ.): 2,1 cm @ 3 m ; 3,5 cm @ 5 m (in proportion to object distance) Emission characteristics: IR laser: wavelength 905 nm;...
  • Page 12 BEA SA | LIEGE SCIENCE PARK | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA-SENSORS.COM BEA hereby declares that the LZR -RS300 is in conformity with the basic requirements and the other ®...