Wiring Schematic; Troubleshooting - BEA CRYSTAL Instruction Manual For Industrial Applications

Infrared presence curtain
Table of Contents

Advertisement

WIRING SCHEMATIC

THRESHOLD PROTECTION used with a motion detector:
The Crystal must be wired in (NO & COM) in parallel with the motion detector.
Door Control
Activate
(NO)
COM
REVERSING DEVICE used with a motion detector:
The Crystal must be wired in (NO & COM) in parallel with the photo eyes.
Reversing
Safety Beams
Switch

TROUBLESHOOTING

SYMPTOM
The LED does not light up
The door opens and closes
continuously
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc.
1-800-523-2462 from 7am - 5pm or 1-800-407-4545 from 5pm - midnight & weekends.
DO NOT leave any problem unresolved. If you must wait for the following workday to call B.E.A., leave the door
NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution.
75.1033 V1 Feb 2001
NO
Activation Device
COM
NO
COM
CORRECTIVE ACTION
1. Check power cable
2. Check power connector
3. Check power supply
1. Increase depth of field (door with handle)
2. Switch dip switch # 4 to ON position (reduced sensitivity)
3. Switch dip switch #1 to OFF position and then back to ON position
for further assistance during Eastern Standard Time at
inoperable until satisfactory repairs can be made.
NO
Crystal
COM
GREEN
NO
Crystal
COM
WHITE
Page 7 of 7