3. Highlight the preferred Autotest and
press F1 (Select) to select it as the Autotest
to run and to return to the Setup screen.
3.1.2 E
DITING
In addition to the pre-programmed
certification standards, CertiFiber allows you to
customize Autotest settings and to develop new
custom Autotests by specifying the PASS/FAIL
limits to be used. To edit an Autotest, take
these steps:
1. From the Autotest setup
screen, use the up- or
down-arrows to highlight
the Autotest you want to
customize and then press
F2 (Edit). A screen like
the one shown at right
appears. If you are
editing an existing
Autotest, the test name
will be preceded with an
asterisk ("*").
2. With the Test Name field highlighted,
press F1 (Edit) to name the Autotest.
Refer to
3. Edit the other test values. (Editable fields
for an
Name, the Loss per Connector, the Loss
per Splice, the Loss per Kilometer for
both wavelengths, the Length, and the
Delay. Editable fields for an Autotest with
fixed PASS/FAIL criteria
the Loss per Kilometer for both
wavelengths, the Length and the Delay.)
A
UTOTESTS
Section 2.8
equation-based
CHAPTER 3: Configuration
.
Autotest are the Test
are the Test Name,