Parameters
12-13 Link Speed
Option:
[0]
None
*
[1]
10 Mbps
[2]
100
Mbps
NOTICE
In POWERLINK this parameter is locked to 100 Mbs.
12-14 Link Duplex
Option:
8
8
[0] Half Duplex
[1] Full Duplex
NOTICE
In POWERLINK this parameter is locked to half duplex.
8.4.3 12-8* Other Ethernet Services
12-80 FTP Server
Option:
[0]
Disabled
*
[1]
Enabled
12-81 HTTP Server
Option:
[0]
Disabled
*
[1]
Enabled
12-82 SMTP Service
Option:
[0]
Disabled
*
[1]
Enabled
12-89 Transparent Socket Channel Port
Range:
Size
related
65535 ]
*
52
Function:
Forces the link speed for each port in 10 Mbps
or 100 Mbps. If parameter 12-12 Auto Negotiation
is set to: ON, this parameter is read only and
displays the actual link speed. If no link is
present, "None" is displayed.
Function:
Forces the duplex for each port to Full or Half
duplex. If 12-12 Auto Negotiation is set to: [ON],
this parameter is read only.
Function:
Disables the built-in FTP server.
Enables the built-in FTP server.
Function:
Enables the built-in HTTP (web) server.
Function:
Enables the SMTP (e-mail) service on the option.
Function:
[ 0 -
Configures the TCP port number for the
transparent socket channel. This config-
uration enables FC telegrams to be sent
transparently on Ethernet via TCP.
Default value is 4000, 0 means disabled.
The MCT 10 Set-up Software uses this
port.
Danfoss A/S © Rev. 2014-02-27 All rights reserved.
Operating Instructions
8.4.4 12-9* Advanced Ethernet Settings
12-90 Cable Diagnostic
Option:
[0]
Disabled
*
[1]
Enabled
NOTICE
The cable diagnostics function is only issued on ports
where there is no link (see 12-10 Link Status, Link Status)
12-91 Auto Cross Over
Option:
[0]
Disabled
[1]
Enabled
*
12-92 IGMP Snooping
Option:
[0]
Disabled Disables the IGMP snooping function.
[1]
Enabled Enables the IGMP snooping function.
*
12-93 Cable Error Length
Range:
0
[0 -
*
65535 ]
12-94 Broadcast Storm Protection
Range:
-1
%
20 %]
*
Function:
Enables/disables advanced Cable diagnosis
function. If enabled, the distance to cable errors
can be read out in parameter 12-93 Cable Error
Length. The parameter resumes to the default
setting of Disable after the diagnostics have
finished.
Function:
Disables the auto cross-over function.
Enables the auto cross-over function.
Function:
This prevents flooding of the Ethernet protocol
stack by only forwarding multicast packets to
ports that are member of the multicast group. In
PROFINET this function is disabled.
Function:
If Cable Diagnostics is enabled in 12-90 Cable
Diagnostic, the built-in switch is possible via Time
Domain Reflectometry (TDR). This measurement
technique detects common cabling problems such
as open circuits, short circuits, and impedance
mismatches or breaks in transmission cables. The
distance from the option to the error is displayed
in meters with an accuracy of ±2 m. The value 0
means that no errors detected.
Function:
[-1 -
The built-in switch is capable of protecting the
switch system from receiving too many broadcast
packages, which can use up network resources.
The value indicates a percentage of the total
bandwidth that is allowed for broadcast
messages.