WATER SUPPLY

C O N N E C T TO P OTA B L E (
WATER PRESSURE REQUIREMENTS: M I N I M U M 30 PSI (2 BAR)
Flush the water line at the installation site before connecting the oven to the water supply. A shut-off valve and
approved back-flow preventer must be installed when connecting the oven to the cold water intake. The water
supply line must be a minimum of 3/4-inch (NPT) (19mm). A hose connector is supplied for flexible hose
connection to the COLD water source. Connected water should test at hardness level of 5 to 9 grains per gallon
(85 to 154 ppm). A water filtration system is recommended if the water supply is between 5 and 9 gpg of
ELBOW
WATER
COLD WATER — DRINKING QUALITY
INDIRECT WASTE PIPE WITH AIR GAP
: 3/4"
INLET
NPT
: less than 0.8 ppm
CHLORINE
: 5 to 9 gpg
HARDNESS
85 to 154 ppm
WATER SOFTENER SHOULD BE UTILIZED
IN HARD WATER AREAS
C O M B I T H E R M
MAXIMUM 90 PSI (6 BAR)
hardness.
installation of a water softener to maintain oven function is strongly
recommended.
PIPE SEALING TAPE
AT ALL CONNECTION POINTS.
The use of a pipe sealing compound is not recommended.
THE SHUT-OFF VALVE MUST BE IN THE OPEN POSITION
WHEN THE OVEN IS BEING USED.
: 1-1/2"
NPT
: 30 to 90 psi
LINE PRESSURE
2 to 6 bar
: less than 70 ppm
CHLORIDE
: 7.0 to 9.0
PH RANGE
.
Alto-Shaam now offers an improved water filtration system for
ITEM
FI-23014
Combitherm®. The CombiGuard™ triple-guard water filtration
system filters dirt, sediment, and other debris as small as 1/2
micron. This system also significantly reduces chlorine content to
protect against corrosive chlorine compounds. CombiGuard
improves equipment efficiency, reduces service requirements and
extends the life of the Combitherm. Filtration system includes one
filter cartridge. Additional cartridges
purchased separately.
# 6 0 0 1
C O M B I T H E R M E L E C T R I C I N S TA L L AT I O N A N D M A I N T E N A N C E M A N UA L
I N S TA L L AT I O N
®
) C O L D WAT E R O N LY
D R I N K A B L E
If water tests over 18 gpg of hardness (344 ppm), the
MUST BE USED
(
)
TEFLON
®
The hand shower spray hose is installed adjacent
to the cold water intake connection. A ball valve
is installed on the oven for hose connection to the
COLD water source. Assemble the washer and
the flexible hose on the ball valve and hang the
spray handle on the holder previously installed
on the oven.
(FI-26356)
can be
. 7
P G

Advertisement

Table of Contents
loading

This manual is also suitable for:

6.10ml10.10ml7.14ml10.18ml12.20ml20.20ml

Table of Contents