Door Chime
Any door contact or PIR set to entry will cause the
control panel to chime when activated when the
system is disarmed. This is used to signal when
anyone has entered your premises. You can switch
the sound on and off with this setting.
• Chime off is the factory default.
Ring Tone
The control panel can be made to beep when the
phone is ringing, you can switch the sound on and
off with this setting.
• Ringing off is the factory default.
Alarm Length
The control panel built in siren will sound when an
alarm is activated. The length of the alarm can be
set from 1 to 15 minutes in 1 minute increments with
this setting.
• 3 minutes is the factory default.
C.U. Siren
You can disable the control panel's built-in siren with
this setting.
• Siren on is the factory default.
Jamming Detection
This setting allow you to turn on and off the radio
signal interference detection. When jamming
detection is turned On, if RF signal jamming lasts for
30 seconds, the fault event will be logged, reported
to the programmed telephone number and displayed
on the LCD to warn the user.Options available are:
Detection On and Detection Off.Detection Off is set
as factory default.
Tamper Alarm
This setting allows any tamper faults to be signaled
by the control panel's built-in siren during disarmed
and home armed conditions when set to normal.
If set to away arm only, it will only give a fault
indication. A tamper condition will always trigger a
burglar alarm when the system is away armed. It is
recommended that you use the normal setting.
• Away Arm Only is the factory default.
RC Entry Enable
This setting allows to decide whether to turn on or
off the Remote Controller disarm function. If turned
Off, the Remote Controller will not be able to disarm
the system unless an entry timer is activated.Options
available are: RC Ent  E On and RC Ent  E Off.RC
Ent  E  Off is set as factory default.
16
Mobility CHK
Mobility check allows remote monitoring of the sick
or infirm, if there is no movement around the house
for a preset period of time, an emergency alarm will
be activated and reported over the telephone line.
This feature operates by having a preset timer that
is reset by activation of any door contact or PIR, the
timer is also reset by any key being pressed on the
control panel and arming and disarming. If the timer
is allowed to expire without a reset, an alarm will be
given. The monitoring can be disabled or 4, 8 and
12 hour periods can be selected.
• Disable is the factory default.
Siren Delay
This setting allows a delay before the control panel
and external sirens are activated. You might want to
use this if you do not want the control panel to draw
attention to itself during an alarm, to give it time to
dial out on the telephone line. The delay can be set
from Disable (no delay) to 10 minutes in increments
of 1 minute.
• Disable is the factory default.
Warning Beep
The control panel will give a reminder beep every
30 seconds in the event of a system fault, such as
tamper or a low battery etc. This setting allows this
feature to be switched on and off.
• Warning on is the factory default.
Time
The control panel uses a 24 hour clock. The time
is set by using the pq keys and confirmed by
pressing the 3 key.
Date
The day and month are set by using the pq keys
and confirmed by pressing the 3 key.
Tel. Settings
This menu allows you to program up to 3 telephone
numbers, record an address message and place
test calls, The following items can be selected.
• Tel. Numbers
• Rec. Address
• Test Report
Tel. Numbers
This menu has a list of 3 telephone numbers ABC.
These numbers are dialed in order, a maximum of 20
digits per number can be stored. Only one number
is required to enable the control panel to report over
the telephone line.

Advertisement